在碱性化合物的亲水作用色谱-电喷雾串联质谱(HILIC-ESI/MS/MS)生物分析中,通过三氟乙酸(TFA)流动相减轻灵敏度损失的简单方法。

Simple means to alleviate sensitivity loss by trifluoroacetic acid (TFA) mobile phases in the hydrophilic interaction chromatography-electrospray tandem mass spectrometric (HILIC-ESI/MS/MS) bioanalysis of basic compounds.

作者信息

Shou Wilson Z, Naidong Weng

机构信息

Covance Laboratories Inc., 3301 Kinsman Boulevard, Madison, WI 53704, USA.

出版信息

J Chromatogr B Analyt Technol Biomed Life Sci. 2005 Oct 25;825(2):186-92. doi: 10.1016/j.jchromb.2005.01.011.

Abstract

Trifluoroacetic acid (TFA) is a commonly used additive in HPLC and LC-MS analysis of basic compounds. It is also routinely added to aqueous-organic mobile phases utilized in the hydrophilic interaction chromatography-electrospray tandem mass spectrometry (HILIC-ESI/MS/MS) technique used in our laboratories for bioanalysis. However, TFA is known to suppress the ESI signals of analytes due to its ability to form gas-phase ion pairs with positively-charged analyte ions. The most common method to overcome this problem involves the post-column addition of a mixture of propionic acid and isopropanol. However the post-column addition setup requires additional pumps and is not desirable for continuous analysis of large amounts of samples. In this paper we present a simple yet very effective means of minimizing the negative effect of TFA in bioanalysis by direct addition of 0.5% acetic acid or 1% propionic acid to mobile phases containing either 0.025 or 0.05% TFA. A factor of two- to five-fold signal enhancement was achieved for eight basic compounds studied. Furthermore, chromatography integrity was maintained even with the addition of acetic acid and propionic acid to existing TFA mobile phases. This method has been successfully applied to the HILIC-ESI/MS/MS high-throughput analysis of extracted biological samples to support pre-clinical and clinical studies.

摘要

三氟乙酸(TFA)是高效液相色谱(HPLC)和液相色谱-质谱联用(LC-MS)分析碱性化合物时常用的添加剂。在我们实验室用于生物分析的亲水作用色谱-电喷雾串联质谱(HILIC-ESI/MS/MS)技术中,它也经常被添加到水-有机流动相中。然而,由于TFA能够与带正电荷的分析物离子形成气相离子对,已知它会抑制分析物的电喷雾信号。克服这个问题最常用的方法是在柱后添加丙酸和异丙醇的混合物。然而,柱后添加装置需要额外的泵,并且对于大量样品的连续分析来说并不理想。在本文中,我们提出了一种简单而非常有效的方法,即通过向含有0.025%或0.05% TFA的流动相中直接添加0.5%的乙酸或1%的丙酸,来最小化TFA在生物分析中的负面影响。对于所研究的八种碱性化合物,信号增强了两到五倍。此外,即使在现有的TFA流动相中添加了乙酸和丙酸,色谱完整性也得以保持。该方法已成功应用于提取的生物样品的HILIC-ESI/MS/MS高通量分析,以支持临床前和临床研究。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验