Suppr超能文献

使用流式细胞术稳定白细胞和免疫标志物以进行扩展分析。

Stabilization of white blood cells and immunologic markers for extended analysis using flow cytometry.

作者信息

Warrino Dominic E, DeGennaro Louis J, Hanson Mary, Swindells Susan, Pirruccello Samuel J, Ryan Wayne L

机构信息

Streck, 7002 S. 109th Street, Omaha, NE 68128, United States.

出版信息

J Immunol Methods. 2005 Oct 30;305(2):107-19. doi: 10.1016/j.jim.2005.01.021.

Abstract

We evaluated whole blood samples drawn from 25 healthy donors and 20 HIV-infected donors into K3EDTA and Cyto-Chex BCT blood collection tubes for CD4, CD8, and CD3 cell counts (HIV Panel). Samples collected in Cyto-Chex BCT were stored at room temperature and tested by 4-color flow cytometry at 6 h, 3 days, and 7 days after isolation for CD4, CD8, and CD3 absolute cell counts/microl and compared with samples collected in K3EDTA tubes and tested at 6 h. Regardless of donor type, the samples collected in Cyto-Chex BCT and tested on day 7 yielded results that were statistically indistinguishable (with correlation coefficients of 0.96 or greater) from samples collected in K3EDTA tubes and tested at 6 h. We conclude that whole blood samples collected in Cyto-Chex BCT are stabilized for their marker phenotype for at least 7 days after phlebotomy.

摘要

我们评估了从25名健康献血者和20名HIV感染献血者采集的全血样本,这些样本被采集到K3EDTA和Cyto-Chex BCT采血管中,用于检测CD4、CD8和CD3细胞计数(HIV检测组)。采集到Cyto-Chex BCT中的样本在室温下保存,并在分离后6小时、3天和7天通过四色流式细胞术检测CD4、CD8和CD3绝对细胞计数/微升,并与采集到K3EDTA管中并在6小时检测的样本进行比较。无论献血者类型如何,采集到Cyto-Chex BCT中并在第7天检测的样本所得到的结果与采集到K3EDTA管中并在6小时检测的样本在统计学上无显著差异(相关系数为0.96或更高)。我们得出结论,采集到Cyto-Chex BCT中的全血样本在采血后至少7天内其标记表型保持稳定。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验