Bao Ye, Lantz Andrew W, Yao Tuanli, Huang Qinhua, Larock Richard C, Armstrong Daniel W
Department of Chemistry, Iowa State University, Ames, IA 50011-3111, USA.
Electrophoresis. 2005 Nov;26(21):4164-71. doi: 10.1002/elps.200500319.
The enantiomeric separations of highly hydrophobic furan derivatives and polycycles were performed and optimized using CD-modified micellar CE. The most effective chiral selector for the enantiomeric separation of these analytes was hydroxypropyl-gamma-CD. The effects of CD and SDS concentration and organic modifier were examined in order to optimize the separation conditions. The ratio of CD to surfactant concentration affected the enantiomeric separation significantly, with increases in the derivatized CD concentration generally enhancing resolution. Addition of an organic solvent modifier to the run buffer served to increase the analytes' solubility and enhance the separation efficiency. A highly acidic pH was necessary to effectively suppress the EOF when operating in the reverse polarity mode.