The laryngeal tube (VBM Medizintechnik, Sulz, Germany) is a relatively new extraglottic airway, designed to secure a patent airway during either spontaneous breathing or controlled ventilation. In this review article, we have assessed the potential role of the laryngeal tube during anaesthesia and during cardiopulmonary resuscitation. There are four variations of the laryngeal tube: standard laryngeal tube, disposable laryngeal tube, laryngeal tube-Suction II and disposable laryngeal tube-Suction II. The design of the device has been revised several times. Insertion of the standard laryngeal tube is as easy as with the laryngeal mask airway classic. The laryngeal tube may provide a better sealing effect than the laryngeal mask. The incidence of complications with the two devices is similar, although the laryngeal tube may require more re-adjustments of its position to obtain a clear airway. Compared with the ProSeal laryngeal mask, the laryngeal tube may be less effective. The efficacy of the standard laryngeal tube is unclear, particularly in patients breathing spontaneously or in children. The efficacy of the laryngeal tube Suction-II and disposable devices is also not clear. From the limited number of studies and reports available, it can be concluded that the laryngeal tube is potentially useful in maintaining a clear airway during anaesthesia and cardiopulmonary resuscitation. In addition, the device may be useful as an aid to tracheal intubation.
喉管(德国苏尔茨的VBM医疗技术公司生产)是一种相对较新的声门外气道装置,旨在在自主呼吸或控制通气期间确保气道通畅。在这篇综述文章中,我们评估了喉管在麻醉和心肺复苏过程中的潜在作用。喉管有四种变体:标准喉管、一次性喉管、喉管-吸痰II型和一次性喉管-吸痰II型。该装置的设计已经多次修订。标准喉管的插入操作与经典喉罩气道一样简便。喉管可能比喉罩提供更好的密封效果。两种装置的并发症发生率相似,尽管喉管可能需要更多次调整位置以确保气道通畅。与双管喉罩相比,喉管的效果可能较差。标准喉管的有效性尚不清楚,尤其是在自主呼吸的患者或儿童中。喉管-吸痰II型及一次性装置的有效性也不明确。从现有的有限数量的研究和报告来看,可以得出结论,喉管在麻醉和心肺复苏期间维持气道通畅方面可能有用。此外,该装置可能有助于气管插管。