Improvement of digital coronary angiography: high resolution processing coupled with a real time functional synchronization procedure.

作者信息

Azancot I, Eiferman C, Le Dref O, Beaufils P, Favereau X, Kedra A W, Slama R

机构信息

Hemodynamic and Image Processing Laboratory, Lariboisière Hospital, Paris, France.

出版信息

Int J Card Imaging. 1992;8(2):109-19. doi: 10.1007/BF01137532.

Abstract

The use of Digital Subtraction Angiography in coronary applications is restricted by the difficulty in: 1. Obtaining a good resolution of the distal branches. 2. Avoiding, for the purpose of subtraction, the motion artifacts induced by artery and background displacement during the cardiac and respiratory cycles. 3. Preserving the dynamic vascular motion. 4. And storing the digital dynamic information on a permanent support. We used for this study an angiography system, based upon a high resolution 45 MIPS-32 Mbyte image processor, interfaced with a 2.75 Gbyte Winchester drive allowing the real time storage of either 30 frames/s in the 5125128 bits matrix or of 7.5 f/s in the 102410248 bits matrix. To preserve the most important dynamic informations on the basis of the 7.5 f/s maximal storage rate, we developed a synchronization device able to recognize in real time, from chronologic delays derived by using both ECG and Aortic Pressure curves, the functional End-Diastolic (ED) and the End-Systolic (ES) positions, even in the case of heart rates varying during the procedure. The ED and the ES images are stored together with the Mid-Systolic (MS), the 1/3-Diastolic (1/3D) and 2/3-Diastolic (2/3D) images. To establish the validity of this sampling method, which uses a reduced number of frames per cardiac cycle, 7200 coronary injections performed during 450 routine coronary angiographies were compared by two independent observers (A and B), using: first a Digital (D) 5 frames/cycle sequence, and secondly a cine Film (F) 50 frames/s sequence acquired immediately after the corresponding D injection. The D technique resulted in the best image and diagnostic quality, particularly when the F quality was estimated 'fair' or 'poor' by both observers, and in an important reduction on X-Ray doses. The visualisation of the sequential ED, MS, ES, 1/3D and 2/3D frames gives the possibility: 1. of saving the dynamic information, as a regular sample of functional images can be displayed with a cine loop technique. 2. of facilitating cardiac synchronized subtractions. 3. of reducing the amount of frames per cycle, thus allowing an important reduction of X-ray doses and the digital and permanent storage of the most important cardiac cycles.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验