Suppr超能文献

多功能隐形眼镜护理液的pH值随时间的变化

pH of multipurpose contact lens solutions over time.

作者信息

López-Alemany A, Montés i Micó R

机构信息

Departament d'Optica, Facultat de Fisica, Universitat de València, Burjassot, València, Spain.

出版信息

Cont Lens Anterior Eye. 1998;21(1):7-10.

Abstract

The pH of nine different brands of multipurpose contact lens solutions available in Spain was determined over a period of 32 days after opening the bottles. Five bottles of nine solutions were used, each of which was buffered and obtained from different manufacturers. The pH measurements were taken using a micropH 2002 Crison pH-meter (accuracy +/- 0.001 pH units). Each solution was measured three times daily over the test period using 10-ml samples taken from the same container. Fluctuations in pH over time were observed but these were within the range of ocular comfort. The average pH of all the solutions tested proved to be between 6.99 and 7.56.

摘要

在西班牙市场上可买到的九种不同品牌的多功能隐形眼镜护理液开封后32天内测定其pH值。使用了九种护理液中的五瓶,每瓶都经过缓冲处理且来自不同制造商。pH值测量使用的是Crison micropH 2002型pH计(精度为±0.001 pH单位)。在测试期间,每天从同一容器中取10毫升样品对每种护理液测量三次。观察到pH值随时间波动,但这些波动在眼部舒适度范围内。所有测试护理液的平均pH值在6.99至7.56之间。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验