PURPOSE

Our purpose was to apply the MCNP4C Monte Carlo (MC) code for dose calculations in the thorax region and compare the results with those of measurements and a conventional treatment planning system (TPS).

MATERIALS AND METHODS

We modeled a Theratron 780E 60Co unit and benchmarked our modeling with percent depth doses (PDDs), beam profiles, and output factors measured in a water phantom. For PDDs and beam profiles, the differences between measurements and MC calculations were less than 1% and 2%, respectively. We used an anatomic thorax phantom for evaluation of a conventional TPS and our MC calculation results.

RESULTS

In comparing the results of calculations and measurements for our thorax geometries, the errors of conventional and MC methods were 20% and 2%, respectively. For the anterior mediastinal field and large thorax field the accuracy of the conventional method was acceptable, but for small fields of lateral thorax irradiation, the error of the conventional method was as high as to 20%. In all MC calculations, discrepancy from the measurements was less than 2%.

CONCLUSION

Our results showed that the MCNP4C MC code could be used in dose calculations in treatment planning for 60Co photon irradiation. In addition, the application of the MC method for dose calculations in radiotherapy with 60Co photons was recommended.

摘要

目的

我们的目的是应用MCNP4C蒙特卡罗(MC)代码进行胸部区域的剂量计算,并将结果与测量值以及传统治疗计划系统(TPS)的结果进行比较。

材料与方法

我们对一台Theratron 780E 60钴治疗机进行建模,并用水模中测量的百分深度剂量(PDD)、射野轮廓和输出因子对我们的模型进行基准测试。对于PDD和射野轮廓,测量值与MC计算值之间的差异分别小于1%和2%。我们使用一个解剖学胸部模体来评估传统TPS和我们的MC计算结果。

结果

在比较我们胸部几何结构的计算结果和测量结果时,传统方法和MC方法的误差分别为20%和2%。对于前纵隔野和大的胸部野,传统方法的准确性是可以接受的,但对于侧胸壁小照射野,传统方法的误差高达20%。在所有MC计算中,与测量值的差异小于2%。

结论

我们的结果表明,MCNP4C MC代码可用于60钴光子照射治疗计划中的剂量计算。此外,推荐将MC方法应用于60钴光子放射治疗的剂量计算。