Hospital Infections Program, Center for Infectious Diseases, Centers for Disease Control, Atlanta, Georgia 30333.
Appl Environ Microbiol. 1984 Apr;47(4):752-6. doi: 10.1128/aem.47.4.752-756.1984.
After an outbreak of peritoneal infections attributed to intrinsic contamination of a poloxamer-iodine solution with Pseudomonas aeruginosa, the manufacturer of the contaminated solution permitted investigation and sampling of materials within the plant. Pseudomonas spp. were recovered from two different unopened lots of solution and from numerous water samples obtained at the plant. The isolates from water identical to those of an isolate recovered from Prepodyne solution (West-Agro Chemical Co., Inc., Westwood, Kans., manufactured for AMSCO Medical Products Div., Erie, Pa.) manufactured 1 month earlier at the same plant. P. aeruginosa was not recovered from incoming city water. P. aeruginosa was recovered from sterile water and poloxamer-iodine after 48 h of incubation in a plant polyvinyl chloride pipe. Scanning electron micrographs of polyvinyl chloride pipe used in the plant showed massive concentrations of rod-shaped and coccobacillary cells apparently embedded in interior deposits of the pipe. Manufacturers of iodophors should be aware that pipes or other surfaces colonized with bacteria may be a source of contamination of their products.
在一批聚氧乙烯-碘溶液由于绿脓假单胞菌的内在污染而引发腹腔感染爆发后,污染溶液的制造商允许对工厂内的材料进行调查和取样。从两个不同的未开封的溶液批次和从工厂获得的大量水样中回收了假单胞菌属。从水中分离出的与从 Prepodyne 溶液(西奥格罗化学公司,堪萨斯州威斯特伍德,为 AMSCO 医疗产品部制造,宾夕法尼亚州伊利)制造的 1 个月前在同一工厂制造的溶液相同的分离物。未从输入的城市水中回收绿脓假单胞菌。在工厂聚氯乙烯管中孵育 48 小时后,从无菌水和聚氧乙烯-碘中回收了绿脓假单胞菌。工厂使用的聚氯乙烯管的扫描电子显微镜照片显示,大量杆状和球杆菌细胞显然嵌入了管内的沉积物中。碘仿制造商应该意识到,可能被细菌殖民的管道或其他表面是其产品污染的来源。