Suppr超能文献

消毒剂对聚氯乙烯(PVC)管内表面定殖的假单胞菌的影响。

Effect of disinfectants on pseudomonads colonized on the interior surface of PVC pipes.

作者信息

Anderson R L, Holland B W, Carr J K, Bond W W, Favero M S

机构信息

Hospital Infections Program, Centers for Disease Control, Atlanta, GA 30333.

出版信息

Am J Public Health. 1990 Jan;80(1):17-21. doi: 10.2105/ajph.80.1.17.

Abstract

We investigated the effect of disinfectants on microbial contamination present on the interior surface of polyvinyl chloride (PVC) pipes filled with 600 ml of water contaminated with Pseudomonas pickettii and P. aeruginosa. After eight weeks, water was removed, and the test pipes exposed to various types of aqueous disinfectants. Disinfectant samples were removed, neutralized, and examined for recovery of microorganisms by membrane filtration. After seven-days exposure, disinfectant solutions were removed and pipes filled with sterile distilled water. Water was examined by membrane filtration at seven-day intervals to determine whether the organisms had survived in the pipes. Colonization of PVC surfaces were examined during each study phase by scanning electron-microscopy (SEM). P. aeruginosa was isolated directly from iodophor disinfectant, phenolic germicide, and iodophor antiseptic solutions. After addition of sterile water, P. aeruginosa was recovered from PVC pipes previously exposed to chlorine, phenolic, quaternary-ammonium, and iodophor disinfectants; P. pickettii was recovered from water in pipes treated with iodophor disinfectant, chlorine, and ethanol. The existence of glycocalyx-like cellular masses on the interior wall of PVC pipes most likely protected embedded organisms from the microbicidal action of some of the disinfectants tested and served as the reservoir for continuous contamination.

摘要

我们研究了消毒剂对聚氯乙烯(PVC)管内表面微生物污染的影响,这些PVC管中装有600毫升被皮氏假单胞菌和铜绿假单胞菌污染的水。八周后,将水排出,然后将测试管暴露于各种类型的水性消毒剂中。取出消毒剂样品,进行中和,并通过膜过滤检查微生物的回收率。暴露七天后,去除消毒剂溶液,并用无菌蒸馏水填充管道。每隔七天通过膜过滤检查水,以确定微生物是否在管道中存活。在每个研究阶段,通过扫描电子显微镜(SEM)检查PVC表面的定植情况。从碘伏消毒剂、酚类杀菌剂和碘伏防腐剂溶液中直接分离出铜绿假单胞菌。加入无菌水后,从先前暴露于氯、酚类、季铵盐和碘伏消毒剂的PVC管中回收了铜绿假单胞菌;从用碘伏消毒剂、氯和乙醇处理过的管道中的水中回收了皮氏假单胞菌。PVC管内壁上存在的类似糖萼的细胞团很可能保护了嵌入的微生物免受某些测试消毒剂的杀菌作用,并作为持续污染的储存库。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/94de/1404551/380b2efceb6d/amjph00214-0011-a.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验