Celiker Alpay, Ozkutlu Süheyla, Karakurt Cemşit, Karagöz Tevfik
Units of Pediatric Cardiology, Department of Pediatrics, Hacettepe University Faculty of Medicine, Ankara, Turkey.
Turk J Pediatr. 2005 Oct-Dec;47(4):323-6.
Transcatheter closure of atrial septal defect (ASD) has been used as an alternative to open heart surgery. Although transcatheter closure of ASD with the Amplatzer septal occluder is a safe and feasible method in pediatric patients, there is little published data on arrhythmia analysis following transcatheter device closure of secundum ASD. We evaluated cardiac dysrhythmias with 24-hour ambulatory electrocardiographic (ECG) monitoring after transcatheter closure of ASD with Amplatzer device. A total of 85 consecutive patients with ASD underwent transcatheter closure of secundum ASD with Amplatzer device between October 1998 and December 2003. The study involved 65 of these patients assessed by 24-hour ambulatory ECG monitoring. Seven patients were evaluated a second time by 24-hour monitorization. During the procedure, transient complete atrioventricular (AV) block was seen in two patients. One of them returned to normal sinus rhythm in catheterization lab and the other returned to normal sinus rhythm in two hours. Transient junctional rhythm was observed in another patient during the device placement. Twenty-four hour ambulatory ECG monitoring was performed on all patients after a mean four-month period (1-12 months). Holter recordings demonstrated rare supraventricular extrasystole in two patients, rare ventricular premature beats in two patients, and intermittent sinus arrest with sinus pause lasting <1.5 seconds in one patient, for a total of five patients (7.6%). In conclusion, dysrhythmias after transcatheter device closure of secundum ASD with Amplatzer device are rare and benign. We need further long-term follow-up to evaluate late dysrhythmias after the transcatheter device closure of secundum ASD.
经导管封堵房间隔缺损(ASD)已被用作心脏直视手术的替代方法。尽管使用Amplatzer房间隔封堵器经导管封堵ASD在儿科患者中是一种安全可行的方法,但关于继发孔型ASD经导管装置封堵后心律失常分析的公开数据很少。我们使用24小时动态心电图(ECG)监测评估了使用Amplatzer装置经导管封堵ASD后的心律失常情况。1998年10月至2003年12月期间,共有85例连续的ASD患者使用Amplatzer装置经导管封堵继发孔型ASD。本研究纳入了其中65例接受24小时动态ECG监测评估的患者。7例患者接受了第二次24小时监测评估。在手术过程中,2例患者出现短暂性完全房室(AV)传导阻滞。其中1例在导管室恢复为正常窦性心律,另1例在两小时后恢复为正常窦性心律。在装置放置过程中,另1例患者出现短暂性交界性心律。平均4个月(1 - 12个月)后,对所有患者进行了24小时动态ECG监测。动态心电图记录显示,2例患者有罕见的室上性期前收缩,2例患者有罕见的室性早搏,1例患者有间歇性窦性停搏且窦性停搏持续时间<1.5秒,共有5例患者(7.6%)。总之,使用Amplatzer装置经导管封堵继发孔型ASD后心律失常罕见且为良性。我们需要进一步的长期随访来评估继发孔型ASD经导管装置封堵后的晚期心律失常情况。