Suppr超能文献

Three-dimensional helical computed tomographic angiography of the liver in five dogs.

作者信息

Winter Matthew D, Kinney Linda M, Kleine Lawrence J

机构信息

Iowa State University College of Veterinary Medicine, Ames, IA 50011, USA.

出版信息

Vet Radiol Ultrasound. 2005 Nov-Dec;46(6):494-9. doi: 10.1111/j.1740-8261.2005.00090.x.

Abstract

The objective of this study was to develop a simple, safe, minimally invasive protocol to evaluate the hepatic vasculature. Five purpose-bred Beagle dogs underwent noncontrast-enhanced computed tomographic scan of the entire abdomen. A dynamic, nonincremental computed tomography scan at the level of T11 was then performed using a test bolus of contrast medium to determine time to peak opacification and to aid in the calculation of scan delay. The time to peak arterial enhancement ranged from 2.0 to 7.0 s, with a median of 2.0 s. The time to peak portal venous enhancement ranged from 23.0 to 46.0 s, with a median of 32.0 s. Scan delay for arterial opacification ranged from 0 to 5.0 s, with a median of 0 s. Scan delay for the portal phase of opacification ranged from 6.0 to 21.0 s, with a median of 17.0 s. Using this information, two separate computed tomographic studies were used to image the arterial and portal venous phases of circulatory opacification, respectively. The dogs were hyperventilated to prevent breathing motion during the scan, each of which required approximately 20 s. A power injector was used to inject diatrizoate meglumine (128 mg I/kg) through an 18-gauge cephalic vein catheter at a rate of 5 ml/s. Scanning was initiated after the appropriate scan delay to optimize the specific phase of vascular filling. Maximum intensity projections allowed clear delineation of the hepatic arteries and the portal venous system, while eliminating overlying structures that might interfere with image analysis. Time/density curves were generated, and the time needed for each study was recorded. Hepatic arteries and portal veins were clearly visualized in all dogs. Parenchymal opacification was also observed.

摘要

相似文献

1
Three-dimensional helical computed tomographic angiography of the liver in five dogs.
Vet Radiol Ultrasound. 2005 Nov-Dec;46(6):494-9. doi: 10.1111/j.1740-8261.2005.00090.x.
2
Dual-phase CT angiography of the normal canine portal and hepatic vasculature.正常犬门静脉和肝血管的双期CT血管造影
Vet Radiol Ultrasound. 2004 Mar-Apr;45(2):117-24. doi: 10.1111/j.1740-8261.2004.04019.x.
3
Helical computed tomographic angiography of the normal canine pancreas.正常犬胰腺的螺旋计算机断层血管造影
Vet Radiol Ultrasound. 2006 May-Jun;47(3):270-8. doi: 10.1111/j.1740-8261.2006.00139.x.
5
[Optimization of the scan delay time of 64-slice spiral CT portal venography].
Nan Fang Yi Ke Da Xue Xue Bao. 2008 Aug;28(9):1573-6, 1578.
8
[Blood supply of liver metastasis].[肝转移瘤的血供]
Beijing Da Xue Xue Bao Yi Xue Ban. 2008 Apr;40(2):146-50.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验