The aim of this investigation was to compare the accuracy and reproducibility of images acquired from two types of camera (digital SLR camera, Kodak DCS410, KJP, UK and an intra-oral camera, Schick Technologies, UK) for application within an imaging system used for the quantification of disclosed dental plaque.
Subjects refrained from brushing their teeth for 24 h. Their teeth were then disclosed with Erythrosin FDC Red 3 and duplicate sets of images were obtained by each examiner of the upper central and lateral incisors. Images were then saved and measured for dental plaque area. These data were used to calculate reliability.
No statistically significant bias in the measurements of plaque area was found. The reliability results showed the method was reliable. However, the image analysis system incorporating the 35 mm SRL camera was more reliable for both operators, as demonstrated by their intra-operator results. This was also collaborated by the inter-operator results.
In this investigation the digital SLR camera combined with the image analysis system and frame permitted greater reliability of dental plaque surface area measurements than the digital intra-oral camera. This conclusion was derived both from the reliability data and from the perceived ease of use and flexibility of both camera types. When combined with the use of the custom-made frame, the images using the digital SLR camera were highly reproducible, confirming the systems application within clinical trials.
本研究旨在比较两种相机(数码单反相机,柯达DCS410,英国KJP公司生产;口腔内相机,英国施克技术公司生产)采集的图像在用于量化已染色牙菌斑的成像系统中的准确性和可重复性。
受试者24小时不刷牙。然后用赤藓红FDC红3对其牙齿进行染色,每位检查者对上颌中切牙和侧切牙获取两组重复图像。图像随后被保存并测量牙菌斑面积。这些数据用于计算可靠性。
在牙菌斑面积测量中未发现统计学上的显著偏差。可靠性结果表明该方法可靠。然而,正如操作员内部结果所示,配备35毫米单反相机的图像分析系统对两位操作员而言都更可靠。操作员之间的结果也证实了这一点。
在本研究中,与数码口腔内相机相比,数码单反相机与图像分析系统及框架相结合,能使牙菌斑表面积测量具有更高的可靠性。这一结论既来自可靠性数据,也来自对两种相机类型易用性和灵活性的感知。当与定制框架配合使用时,数码单反相机拍摄的图像具有高度可重复性,证实了该系统在临床试验中的应用。