64排0.6毫米准直和330毫秒旋转时间的多排螺旋计算机断层扫描用于无创检测显著冠状动脉狭窄的效用。

Usefulness of multidetector row spiral computed tomography with 64- x 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses.

作者信息

Ropers Dieter, Rixe Johannes, Anders Katharina, Küttner Axel, Baum Ulrich, Bautz Werner, Daniel Werner G, Achenbach Stephan

机构信息

Department of Internal Medicine II, University of Erlangen, Erlangen, Germany.

出版信息

Am J Cardiol. 2006 Feb 1;97(3):343-8. doi: 10.1016/j.amjcard.2005.08.050. Epub 2005 Dec 1.

Abstract

Eighty-four patients with suspected coronary artery disease were studied to determine the accuracy of noninvasive coronary angiography using a multidetector computed tomographic scanner with 64- x 0.6-mm collimation and 330-ms gantry rotation. All coronary artery segments with a diameter >1.5 mm were assessed with respect to stenoses >50% decreased diameter. Results were compared with quantitative coronary angiographic findings. After exclusion of unevaluable coronary segments (4%), multidetector computed tomography demonstrated a sensitivity of 93%, a specificity of 97%, and a negative predictive value of 100% in a per-segment analysis. In a per-artery analysis, 15 of 336 arteries (4%) were unevaluable. Sensitivity and specificity in evaluable arteries were 95% and 93%, respectively. In a per-patient analysis (81 of 84 patients included), sensitivity and specificity were 96% and 91%, respectively.

摘要

对84例疑似冠心病患者进行了研究,以确定使用具有64×0.6毫米准直和330毫秒机架旋转的多排螺旋计算机断层扫描仪进行无创冠状动脉造影的准确性。对所有直径>1.5毫米的冠状动脉节段进行评估,观察直径减少>50%的狭窄情况。将结果与定量冠状动脉造影结果进行比较。在排除不可评估的冠状动脉节段(4%)后,多排螺旋计算机断层扫描在节段分析中的敏感性为93%,特异性为97%,阴性预测值为100%。在动脉分析中,336条动脉中有15条(4%)不可评估。可评估动脉的敏感性和特异性分别为95%和93%。在患者分析中(纳入84例患者中的81例),敏感性和特异性分别为96%和91%。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验