Suppr超能文献

Radial head prosthesis after fracture of radial head with associated elbow instability.

作者信息

Wretenberg Per, Ericson Anne, Stark André

机构信息

Department of Orthopaedics, Karolinska University Hospital, SE-171, 76 Stockholm, Sweden.

出版信息

Arch Orthop Trauma Surg. 2006 Apr;126(3):145-9. doi: 10.1007/s00402-005-0032-2. Epub 2006 Feb 9.

Abstract

INTRODUCTION

Fractures of the radial head and associated elbow instability can be treated with operation with radial head prosthesis. In this study, we evaluate function 1-7 years after implantation and also function after removal of five prostheses.

MATERIAL AND METHODS

Eighteen patients with radial head fracture and associated elbow instability were evaluated 3.7 years (1-7) after implantation of a radial head prosthesis. Pain at rest and during activity was measured with a visual analogue scale (VAS). Test of stability and neurological examination was done manually as well as measurement of the range of motion, using a goniometer. Activity of daily living (ADL) was estimated using five questions where the answers were graded between 1 and 3. The patients were asked to grade their general satisfaction according to the following scale; very satisfied, satisfied, not satisfied, disappointed. Plain X-rays were taken and 14 patients agreed to have their elbow strength evaluated using the validated BTE work simulator.

RESULTS

Five prostheses had been extracted due to poor range of motion. All these patients improved after extraction. All elbows were stable. No patient with extracted prosthesis had VAS score >2. The mean extension defect for this group was 15 degrees (5-25) compared to the mean extension defect for the 13 patients with the prosthesis still in place 15 degrees (0-40). The highest VAS score for the patients with prosthesis was five but the mean as low as 0.8. In the whole group, 13 patients were pain free. ADL function was good in general. The X-rays of the prostheses, still in place, showed radiolucent lines in 7 of the 13 patients. In the whole group, there was a significant decrease in supination, flexion and extension strength (P<0.01, P<0.01, P<0.05).

DISCUSSION

Radial head prosthesis works as a spacer after fracture of the radial head and associated instability. If range of motion is much restricted post-operatively, the prosthesis can be removed with improved function as result.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验