Suppr超能文献

记录视网膜电图(ERG)和多焦视网膜电图中的明视和暗视反应。

Recording rod ON and OFF responses in ERG and multifocal ERG.

作者信息

Chen Changzheng, Zuo Chengguo, Piao Changhua, Miyake Yozo

机构信息

The department of ophthalmology, Remin Hospital of Wuhan University, 430060, China.

出版信息

Doc Ophthalmol. 2005 Sep;111(2):73-81. doi: 10.1007/s10633-005-4267-6. Epub 2006 Mar 2.

Abstract

The 5 Hz rectangle stimulus was generally used to record cone ON and OFF response. In this study, the feasibility and recording conditions of recording rod ON and OFF responses in electroretinograms (ERG) and multifocal electroretinograms (mf-ERG) were described, and the character and influence factors of these responses were observed. The result demonstrated that the rod ON and OFF responses of ERG can be recorded with sawtooth rapid-on and rapid-off stimulus. There is a small positive wave in downhill of negative wave in rod OFF response. Rod ON response of mf-ERG can be recorded with simulated rapid-on stimulus. We speculated that the simulated rapid-ON, sawtooth rapid-on and rapid-off stimulus can be an useful tool to investigate retinal disease and have certain clinical values.

摘要

5Hz矩形刺激通常用于记录视锥细胞的开和关反应。在本研究中,描述了在视网膜电图(ERG)和多焦视网膜电图(mf-ERG)中记录视杆细胞开和关反应的可行性及记录条件,并观察了这些反应的特征和影响因素。结果表明,ERG的视杆细胞开和关反应可用锯齿状快速开和快速关刺激来记录。视杆细胞关反应的负波下降支中有一个小的正波。mf-ERG的视杆细胞开反应可用模拟快速开刺激来记录。我们推测,模拟快速开刺激、锯齿状快速开和快速关刺激可能是研究视网膜疾病的有用工具,具有一定的临床价值。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验