Kärrholm Johan, Hourigan Patrick, Timperley John, Razaznejad Reza
Department of Orthopaedics, Sahlgrenska Hospital, Göteborg University, SE-413 45 Göteborg, Sweden.
Acta Orthop. 2006 Feb;77(1):39-48. doi: 10.1080/17453670610045687.
Bone morphogenetic proteins (BMPs) have the potential to improve incorporation of allograft bone in revision surgery. This could result in improved fixation and graft incorporation.
We evaluated the effect of mixing OP-1 (BMP-7) with morselized allograft in hip revisions. In a case-control study, 20 acetabular revisions (10 in the study group, 10 controls) and 41 femoral revisions (11 in study group, 30 controls) were done using impaction allografting. The migration of the cups and stems was studied with radiostereometric analysis (RSA) for up to 5 years. Changes of bone mineral density around the femoral component were measured with dual energy X-ray adsorptiometry for 2 years. Bone remodeling and the extent of radiolucent lines were evaluated on conventional radiographs after 5 years. The clinical results were documented using Harris hip score.
In the cup study, there was no significant difference in implant migration between the study and control groups. 4 sockets in the study group were classified as radiographically loose after 5 years and 2 of them were revised after 5 years. After 2 years, the stems in the study group showed slightly increased posterior tilt (0.3 degrees , p = 0.03). 1 stem in the study group loosened and was revised during the third year of observation.
The sample size and study design in our evaluation did not allow any firm conclusions. Absence of any trend to improved fixation and early revisions in the study group prompted us to stop recruitment to this study.
骨形态发生蛋白(BMPs)有潜力在翻修手术中改善同种异体骨的融合。这可能会改善固定效果和移植物融合情况。
我们评估了在髋关节翻修术中将OP-1(BMP-7)与碎异体骨混合的效果。在一项病例对照研究中,采用打压植骨术进行了20例髋臼翻修术(研究组10例,对照组10例)和41例股骨翻修术(研究组11例,对照组30例)。采用放射立体测量分析(RSA)对髋臼杯和股骨柄的移位情况进行了长达5年的研究。使用双能X线吸收法测量股骨假体周围骨密度变化,为期2年。5年后在传统X线片上评估骨重塑情况和透亮线范围。使用Harris髋关节评分记录临床结果。
在髋臼杯研究中,研究组与对照组之间的假体移位无显著差异。5年后研究组有4个髋臼杯在X线片上被归类为松动,其中2个在5年后进行了翻修。2年后,研究组的股骨柄后倾略有增加(0.3度,p = 0.03)。研究组有1个股骨柄在观察的第三年出现松动并进行了翻修。
我们评估中的样本量和研究设计不允许得出任何确凿结论。研究组中缺乏固定改善和早期翻修的任何趋势促使我们停止了这项研究的招募工作。