OBJECTIVE

We wanted to assess the usefulness of four-dimensional (4D) ultrasonography (US), i.e., real-time three-dimensional US, as an adjunct for performing various US-guided interventional procedures in superficial lesions.

MATERIALS AND METHODS

Thirty-three patients were referred for US-guided interventional procedures for superficial lesions, including core biopsy in 19, fine-needle aspiration in eight, therapeutic drug injection in four and needle puncture in two. The procedures were performed under 4D US guidance. We reviewed the pathologic/cytologic results of the core biopsies or needle aspirations, and also the outcomes of drug injection or needle puncture.

RESULTS

For all the patients who underwent 4D US-guided core biopsy, the specimens were adequate for making the pathological diagnosis, and specimens were successfully obtained for those patients who underwent 4D US-guided aspiration. The patients treated with 4D US-guided therapeutic drug injection or needle puncture had a good response. No major procedure-related complications occurred. The procedural times were similar to those procedural times with using two-dimensional US.

CONCLUSION

Combining the two dimensional and 4D US techniques aids the physician when performing US-guided interventional procedures for the superficial lesions.

摘要

目的

我们旨在评估四维(4D)超声检查(US),即实时三维超声,作为在浅表病变中进行各种超声引导介入操作辅助手段的实用性。

材料与方法

33例患者因浅表病变接受超声引导介入操作,其中19例行粗针活检,8例行细针穿刺抽吸,4例行治疗性药物注射,2例行针刺。操作在4D超声引导下进行。我们回顾了粗针活检或针吸活检的病理/细胞学结果,以及药物注射或针刺的结果。

结果

所有接受4D超声引导粗针活检的患者,标本均足以做出病理诊断,接受4D超声引导针吸活检操作的患者成功获取了标本。接受4D超声引导治疗性药物注射或针刺的患者反应良好。未发生与操作相关的重大并发症。操作时间与使用二维超声时相似。

结论

在对浅表病变进行超声引导介入操作时,结合二维和4D超声技术对医生有帮助。