In this study, we examined intertester reliability of dynamic and static balance using the Chattecx Dynamic Balance System. Ten female and two male subjects were randomly assigned to two testers and completed ten, 10-second preprogrammed double- and single-leg test conditions. Balance was measured as postural sway in centimeters by the Chattecx Dynamic Balance System. Static balance consisted of the platform remaining stable, whereas dynamic balance consisted of the platform tilting in an anterior and posterior direction during testing. The protocols and average postural sway values were:1. Double-Leg Static Eyes Open ([unk] = .28 cm)2. Double-Leg Static Eyes Closed ([unk] = .37 cm)3. Double-Leg Dynamic Eyes Open ([unk] = .86 cm)4. Double-Leg Dynamic Eyes Closed ([unk] = 1.72 cm)5. Single-Leg Static Dominant Eyes Open ([unk] = .99 cm)6. Single-Leg Static Dominant Eyes Closed ([unk] = 1.70 cm)7. Single-Leg Static Nondominant Eyes Open ([unk] = .65 cm)8. Single-Leg Static Nondominant Eyes Closed ([unk] = 1.48 cm)9. Single-Leg Dynamic Dominant Eyes Open ([unk] = .99cm)10. Single-Leg Dynamic Nondominant Eyes Open ([unk] = .91 cm).The mean values of postural sway ranged from .28 cm to 1.72 cm for double-leg stance measures and from .65 cm to 1.70 cm for the single-leg stance measures. The intraclass correlations (ICCs)(2,1) ranged from poor to excellent (ICCs = .06 to .90) and the standard error of measurement (SEM) ranged from .06 to .34 for the 10 trials. We feel that variability exists between subjects and/or testers between trials. The wide range of reliability values suggests that further research should determine both intratester and intertester reliability using a variety of protocols for assessment of static and dynamic balance.

摘要

在这项研究中,我们使用 Chattecx 动态平衡系统检查了动态和静态平衡的测试者间可靠性。十位女性和两位男性受试者被随机分配给两位测试者,并完成了十次 10 秒的预编程双腿和单腿测试条件。平衡通过 Chattecx 动态平衡系统以厘米为单位测量为姿势摆动。静态平衡由平台保持稳定组成,而动态平衡由测试期间平台向前后倾斜组成。方案和平均姿势摆动值为:1. 双腿静态睁眼(ICC(2,1)=.28cm)2. 双腿静态闭眼(ICC(2,1)=.37cm)3. 双腿动态睁眼(ICC(2,1)=.86cm)4. 双腿动态闭眼(ICC(2,1)= 1.72cm)5. 单腿静态优势眼睁眼(ICC(2,1)=.99cm)6. 单腿静态优势眼闭眼(ICC(2,1)= 1.70cm)7. 单腿静态非优势眼睁眼(ICC(2,1)=.65cm)8. 单腿静态非优势眼闭眼(ICC(2,1)= 1.48cm)9. 单腿动态优势眼睁眼(ICC(2,1)=.99cm)10. 单腿动态非优势眼睁眼(ICC(2,1)=.91cm)。姿势摆动的平均值范围为双腿站立测量的 0.28cm 至 1.72cm,单腿站立测量的 0.65cm 至 1.70cm。组内相关系数(ICC)(2,1)范围从差到优(ICC=.06 至.90),10 次试验的测量误差范围从 0.06 至 0.34。我们认为,在试验之间,受试者和/或测试者之间存在变异性。可靠性值的广泛范围表明,应该使用各种评估静态和动态平衡的方案进一步确定组内和组间的可靠性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5711/1317868/ee5aa51472d6/jathtrain00023-0048-a.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验