Papasouliotis K, Dodkin S, Murphy K, Woloszczuk G, Fleming M
Small Animal Hospital, School of Clinical Veterinary Science, University of Bristol, Langford BS40 5DU, Bristol.
J Small Anim Pract. 2006 Apr;47(4):190-5. doi: 10.1111/j.1748-5827.2006.00091.x.
Kuadro is a new wet-reagent biochemistry analyser that is available for in-house use. The aim of this study was to compare the results produced by this analyser with those obtained by a wet-reagent analyser (KoneLab 30i) that served as the reference instrument.
Blood samples from 80 clinical cases (40 dogs and 40 cats) were analysed for urea, creatinine, total proteins, albumin, glucose, cholesterol, alanine aminotransferase, alkaline phosphatase, total bilirubin, amylase, total calcium, and phosphate using both the reference and Kuadro instruments.
Kuadro performed very well on canine and feline samples, showing clinically acceptable correlations (r value) (canine/feline) for urea (0.99/0.97), creatinine (0.99/0.98), total proteins (0.95/0.97), albumin (0.98/0.90), glucose (0.99/0.99), cholesterol (0.99/0.99), alanine aminotransferase (1.00/0.99), alkaline phosphatase (0.96/0.99), total bilirubin (1.00/1.00), amylase (0.98/0.96), and phosphate (0.91/0.92). The correlation for total calcium measurements was clinically unacceptable (0.78/0.83).
Urea, creatinine, albumin, glucose, cholesterol, alanine aminotransferase, and phosphate Kuadro values can be used interchangeably with those generated by the reference analyser. Alkaline phosphatase, amylase, and total proteins Kuadro values cannot be used interchangeably, as Kuadro overestimated alkaline phosphatase and amylase and underestimated total protein measurements. Kuadro significantly underestimated total calcium concentrations due to the shorter incubation time used by the Kuadro analyser compared with the incubation time used in the reference analyser assay system.
Kuadro是一款可供内部使用的新型湿试剂生化分析仪。本研究的目的是将该分析仪产生的结果与作为参考仪器的湿试剂分析仪(KoneLab 30i)所获得的结果进行比较。
使用参考仪器和Kuadro仪器对80例临床病例(40只犬和40只猫)的血液样本进行尿素、肌酐、总蛋白、白蛋白、葡萄糖、胆固醇、丙氨酸氨基转移酶、碱性磷酸酶、总胆红素、淀粉酶、总钙和磷酸盐分析。
Kuadro在犬类和猫类样本上表现良好,尿素(0.99/0.97)、肌酐(0.99/0.98)、总蛋白(0.95/0.97)、白蛋白(0.98/0.90)、葡萄糖(0.99/0.99)、胆固醇(0.99/0.99)、丙氨酸氨基转移酶(1.00/0.99)、碱性磷酸酶(0.96/0.99)、总胆红素(1.00/1.00)、淀粉酶(0.98/0.96)和磷酸盐(0.91/0.92)显示出临床上可接受的相关性(r值)(犬/猫)。总钙测量的相关性在临床上不可接受(0.78/0.