Suppr超能文献

比格犬的心电图:参考值及性别、遗传品系、体位和心率的影响

The electrocardiogram of the Beagle dog: reference values and effect of sex, genetic strain, body position and heart rate.

作者信息

Hanton G, Rabemampianina Y

机构信息

Department of Toxicology and Comparative Medicine, Pfizer Global Research and Development, Amboise, France.

出版信息

Lab Anim. 2006 Apr;40(2):123-36. doi: 10.1258/002367706776319088.

Abstract

The aim of the study was to establish a database for electrocardiographic parameters of Beagle dogs used for toxicological studies and to evaluate the influence of supplier, sex, heart rate (HR) and body position for electrocardiogram (ECG) recording on ECG parameters. Peripheral ECG leads were recorded from 934 female and 946 male dogs from Marshall Farms and 27 females and 30 males from Harlan, either standing on a table or restrained in a hammock. HR, RR, PQ and QT intervals, P and QRS duration and P-wave amplitude were measured. There were no major differences between sexes for ECG parameters. The axis of the heart was shifted to the left when the animals were restrained in a hammock compared to when they were standing on a table. The PQ interval was higher (about 9%) in Harlan than in Marshall dogs. HR was negatively correlated with QT (coefficient of linear correlation: r=-0.61 to -0.74), which emphasizes the need for a formula correcting QT interval for HR when interpreting changes in QT interval. HR was also negatively correlated with PQ intervals (r=-0.26 to -0.11), whereas a positive correlation was found between HR and the amplitude of the P wave (r=0.21-0.34). The level of the respiratory sinus arrhythmia (SA) was quantified by calculating the ratio of maximum to minimum RR interval measured over a 10 s period. This ratio was negatively correlated with HR (r =-0.49 to -0.33). Therefore, at high HRs, SA was less marked than at low HRs, but it did not completely disappear. Analysis of beat-to-beat variation indicated that QT and PQ intervals and the amplitude of P wave fluctuated over time and the degree of this variability was positively correlated with the level of SA. In conclusion, we have established reference values for the duration and/or amplitude of some ECG parameters both in terms of means and variability over the recording period, and we have evaluated the influence of body position, genetic strain and HR on the ECG parameters. These data can be used as baseline for the interpretation of the ECG of Beagle dogs.

摘要

本研究的目的是建立用于毒理学研究的比格犬心电图参数数据库,并评估供应商、性别、心率(HR)和心电图(ECG)记录时的体位对心电图参数的影响。从马歇尔农场的934只雌性和946只雄性犬以及哈兰的27只雌性和30只雄性犬记录外周心电图导联,这些犬要么站在桌子上,要么被限制在吊床中。测量了HR、RR、PQ和QT间期、P和QRS时限以及P波振幅。心电图参数在性别之间没有重大差异。与站在桌子上相比,当动物被限制在吊床中时,心脏轴向左偏移。哈兰犬的PQ间期比马歇尔犬高(约9%)。HR与QT呈负相关(线性相关系数:r = -0.61至-0.74),这强调了在解释QT间期变化时需要一个根据HR校正QT间期的公式。HR与PQ间期也呈负相关(r = -0.26至-0.11),而HR与P波振幅呈正相关(r = 0.21 - 0.34)。通过计算10秒内测量的最大RR间期与最小RR间期的比值来量化呼吸性窦性心律失常(SA)的水平。该比值与HR呈负相关(r = -0.49至-0.33)。因此,在高HR时,SA不如在低HR时明显,但并未完全消失。逐搏变化分析表明,QT和PQ间期以及P波振幅随时间波动,这种变异性程度与SA水平呈正相关。总之,我们已经建立了一些心电图参数的持续时间和/或振幅的参考值,包括记录期间的均值和变异性,并且我们已经评估了体位、遗传品系和HR对心电图参数的影响。这些数据可作为解释比格犬心电图的基线。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验