Tatsugami F, Matsuki M, Kani H, Tanikake M, Miyao M, Yoshikawa S, Narabayashi I
Department of Radiology, Osaka Medical College, Takatsuki City, Osaka, Japan.
Acta Radiol. 2006 Mar;47(2):192-7. doi: 10.1080/02841850500479636.
To investigate whether saline pushing after contrast material improves hepatic vascular and parenchymal enhancement, and to determine whether this technique permits decreased contrast material concentration.
120 patients who underwent hepatic multidetector computed tomography were divided randomly into four groups (Groups A-D): receiving 100 ml of contrast material (300 mgI/ml) only (A) or with 50 ml of saline solution (B); or 100 ml of contrast material (350 mgI/ml) only (C) or with 50 ml of saline solution (D). Computed tomography (CT) values of the aorta in the arterial phase, the portal vein in the portal venous inflow phase, and the liver in the hepatic phase were measured. Visualization of the hepatic artery and the portal vein by 3D CT angiography was evaluated as well.
Although the enhancement values of the aorta were not improved significantly with saline pushing, they continued at a high level to the latter slices with saline pushing. The enhancement value of the portal vein increased significantly and CT portography was improved with saline pushing. The enhancement value of the liver was not improved significantly using saline pushing. In a comparison between groups B and C, the enhancement values of the aorta and portal vein and the visualization of CT arteriography and portography were not statistically different.
The saline pushing technique can contribute to a decrease in contrast material concentration for 3D CT arteriography and portography.
研究造影剂注射后推注生理盐水是否能改善肝脏血管和实质的强化,并确定该技术是否能降低造影剂浓度。
120例行肝脏多排螺旋CT检查的患者被随机分为四组(A - D组):仅接受100 ml造影剂(300 mgI/ml)(A组)或同时接受50 ml生理盐水(B组);或仅接受100 ml造影剂(350 mgI/ml)(C组)或同时接受50 ml生理盐水(D组)。测量动脉期主动脉、门静脉流入期门静脉以及肝期肝脏的CT值。同时评估三维CT血管造影对肝动脉和门静脉的显示情况。
虽然推注生理盐水后主动脉的强化值未显著提高,但在推注生理盐水的后续层面中其强化值持续保持在较高水平。推注生理盐水后门静脉的强化值显著增加,CT门静脉造影得到改善。推注生理盐水对肝脏的强化值无显著改善。在B组和C组的比较中,主动脉和门静脉的强化值以及CT动脉造影和门静脉造影的显示情况无统计学差异。
推注生理盐水技术有助于降低三维CT动脉造影和门静脉造影的造影剂浓度。