Department of Radiology, University of Yamanashi, Yamanashi, Japan.
Eur J Radiol. 2012 Sep;81(9):2450-5. doi: 10.1016/j.ejrad.2011.06.022. Epub 2011 Jun 25.
To clarify the optimal iodine dose of contrast material for 3-dimensional multidetector-row CT angiography (3D-MDCTA) of the venous vasculature of the liver using volume rendering technique.
This study included 103 patients who were randomly assigned to 5 contrast-enhanced MDCT protocol groups with different body-weight-tailored doses of contrast material: 500, 600, 630, 650, and 700 mgI/kg body weight. The arterial, portal, and hepatic parenchymal phases were obtained to evaluate enhancement values of the aorta, portal vein, and hepatic vein. Visualization of the portal and hepatic veins on the volume-rendering images of 3D-MDCTA was evaluated using a 5-point grade. Dunnett's test was used to compare the mean enhancement value and mean grades of image quality (700 mgI/kg dose group was control).
The mean enhancement values of portal and hepatic vein in the group with 500 and 600 mgI/kg were significantly lower than those of the control group. During visual assessment, a significantly lower mean grades were observed in 500 mgI/kg groups for the portal vein, and 500 and 600 mgI/kg groups for hepatic vein. There were no significant intergroup differences in mean enhancement values and visual assessment among the groups using 630 mgI/kg or more.
Iodine doses of 630 mgI/kg was recommended for 3D-MDCTA.
使用容积再现技术明确用于肝脏静脉血管 3 维多层 CT 血管造影(3D-MDCTA)的对比剂最佳碘剂量。
本研究纳入了 103 例患者,他们被随机分配到 5 组不同体质量定制对比剂剂量的增强 MDCT 协议组:500、600、630、650 和 700mgI/kg 体质量。获得动脉期、门静脉期和肝实质期,以评估主动脉、门静脉和肝静脉的增强值。使用 5 分制评估 3D-MDCTA 容积再现图像上门静脉和肝静脉的可视化。采用 Dunnett 检验比较平均增强值和图像质量的平均等级(700mgI/kg 剂量组为对照组)。
500 和 600mgI/kg 组门静脉和肝静脉的平均增强值明显低于对照组。在视觉评估中,500mgI/kg 组门静脉和 500mgI/kg 组和 600mgI/kg 组肝静脉的平均等级明显较低。使用 630mgI/kg 或更高剂量的各组之间,平均增强值和视觉评估无显著组间差异。
建议使用 630mgI/kg 的碘剂量进行 3D-MDCTA。