Suppr超能文献

青光眼客观诊断测试的比较:海德堡视网膜断层扫描与多焦视觉诱发电位

Comparison of objective diagnostic tests in glaucoma: Heidelberg retinal tomography and multifocal visual evoked potentials.

作者信息

Balachandran C, Graham S L, Klistorner A, Goldberg I

机构信息

Save Sight Institute, Department of Ophthalmology, Sydney University, Sydney, Australia.

出版信息

J Glaucoma. 2006 Apr;15(2):110-6. doi: 10.1097/00061198-200604000-00006.

Abstract

PURPOSE

To compare sensitivity and specificity of functional and structural changes in glaucoma using two objective tests: the multifocal visual evoked potential (m-VEP) and Heidelberg retinal tomography II (HRT).

PATIENTS AND METHODS

41 glaucoma patients and 25 normal individuals participated in the study. One eye per individual was included in the study. Individuals were evaluated with Humphrey visual field (HVF) perimetry, m-VEP, and HRT. Moorfield regression analysis findings of HRT were compared with presence of scotoma on m-VEP. Linear regression analysis of quantitative variables, such as HVF mean deviation (MD), m-VEP discriminant score (Accumap Severity Index) and, global HRT parameters was also performed.

RESULTS

m-VEP sensitivity and specificity were 93% and 96% respectively. HRT sensitivity and specificity were 79% and 92% respectively. The area under the receiver operating characteristic curve (ROC) for m-VEP was 0.96 and for HRT varied from 0.79 to 0.86 depending on the parameters used. Linear correlation between MD and Accumap Severity Index score was -77%, while that between HRT global parameters, Accumap Severity Index and MD were at best around 50%. Topographic comparison of the presence of scotoma on HVF and m-VEP in different areas of the visual field showed good agreement. Comparison of optic nerve head structural abnormality with corresponding areas of field defects on HVF and m-VEP showed poor to moderate agreement.

CONCLUSION

The objective test of optic nerve function (m-VEP) and structure (HRT) can detect glaucomatous damage, with limited correlation. The 2 functional tests, HVF and m-VEP correlate better with each other than with HRT. It remains important to look for both functional and structural changes in order to detect all glaucoma cases.

摘要

目的

使用两种客观测试方法,即多焦视觉诱发电位(m-VEP)和海德堡视网膜断层扫描II(HRT),比较青光眼功能和结构改变的敏感性和特异性。

患者和方法

41例青光眼患者和25名正常个体参与了该研究。每个人的一只眼睛纳入研究。对个体进行了 Humphrey 视野(HVF)检查、m-VEP 检查和 HRT 检查。将 HRT 的 Moorfield 回归分析结果与 m-VEP 上暗点的存在情况进行比较。还对 HVF 平均偏差(MD)、m-VEP 判别分数(累积地图严重指数)和全局 HRT 参数等定量变量进行了线性回归分析。

结果

m-VEP 的敏感性和特异性分别为 93%和 96%。HRT 的敏感性和特异性分别为 79%和 92%。m-VEP 的受试者操作特征曲线(ROC)下面积为 0.96,HRT 的 ROC 下面积根据所使用的参数在 0.79 至 0.86 之间变化。MD 与累积地图严重指数分数之间的线性相关性为-77%,而 HRT 全局参数、累积地图严重指数与 MD 之间的相关性最高约为 50%。视野不同区域 HVF 和 m-VEP 上暗点存在情况的地形图比较显示出良好的一致性。视神经乳头结构异常与 HVF 和 m-VEP 上相应视野缺损区域的比较显示出较差至中等程度的一致性。

结论

视神经功能(m-VEP)和结构(HRT)的客观测试可以检测青光眼性损害,但相关性有限。两种功能测试,即 HVF 和 m-VEP 之间的相关性比它们与 HRT 之间的相关性更好。为了检测所有青光眼病例,同时寻找功能和结构改变仍然很重要。