Gemalmaz D, Kükrer D
Department of Prosthetic Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkey.
J Oral Rehabil. 2006 Jun;33(6):436-42. doi: 10.1111/j.1365-2842.2005.01562.x.
The aim of this study was to evaluate the marginal adaptation of class II ceromer (Targis, Vivadent) indirect inlay restorations under both in vivo and in vitro conditions. Twenty Targis inlays were produced for class II inlay cavities (13 mandibular and seven maxillary teeth) in 20 patients. The in vivo adaptation of the inlay to the tooth cavity was evaluated by means of silicone replica technique. For in vitro evaluation, 20 mesio-occluso-distal (MOD) Targis inlays were made in extracted upper molars. Half of the inlays were cemented with Variolink high-viscosity resin cement while the other half was cemented with Variolink Ultra. The replica specimens and in vitro samples were sectioned buccolingually and mesiodistally, and marginal adaptation was evaluated at both proximal and occlusal margins at 200x magnification under a light microscope. The data was analyzed with anova (P < 0.05). The in vivo mean film thickness values for occlusal and proximal locations were recorded as 73 and 132 microm respectively. In vitro mean marginal fit values were observed as 48 and 67 microm for occlusal and proximal margins of inlays luted with Variolink II high viscosity. The marginal fit values recorded under in vivo conditions were higher in magnitude than the measurements obtained under in vitro conditions. The use of a highly filled resin luting agent with an ultrasonic insertion technique did not cause an increase in marginal gap width of the inlay.
本研究的目的是评估II类瓷聚体(Targis,Vivadent)间接嵌体修复体在体内和体外条件下的边缘适合性。为20例患者的II类嵌体窝洞(13颗下颌牙和7颗上颌牙)制作了20个Targis嵌体。通过硅橡胶复制技术评估嵌体与牙洞的体内适合性。为进行体外评估,在拔除的上颌磨牙上制作了20个近中-咬合-远中(MOD)Targis嵌体。一半的嵌体用Variolink高粘度树脂水门汀粘结,另一半用Variolink Ultra粘结。将复制标本和体外样本沿颊舌向和近远中向切片,在光学显微镜下以200倍放大率评估近中边缘和咬合边缘的边缘适合性。采用方差分析对数据进行分析(P<0.05)。记录的咬合面和近中面位置的体内平均膜厚度值分别为73和132微米。对于用Variolink II高粘度粘结的嵌体,其咬合边缘和近中边缘的体外平均边缘适合度值分别为48和67微米。体内条件下记录的边缘适合度值在数值上高于体外条件下获得的测量值。使用高度填充的树脂粘结剂并采用超声插入技术不会导致嵌体边缘间隙宽度增加。