Saenger Amy K, Laha Thomas J, Bremner Deborah E, Sadrzadeh Sayed M H
Department of Laboratory Medicine, University of Washington Medical Center and Harborview Medical Center, Seattle, WA 98195, USA.
Am J Clin Pathol. 2006 Jun;125(6):914-20. doi: 10.1309/J32U-F7GT-QPWN-25AP.
Serum levels of 25-hydroxyvitamin D are important in establishing true vitamin D levels in humans. The purposes of this study were to develop a sensitive, specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for detection of 25-hydroxyvitamin D(2) and D(3) and establish reference intervals for these analytes. Chromatographic separation of 25(OH)D(2) and 25(OH)D(3) was achieved after adding deuterated Delta(9)-tetrahydrocannabinol (D(9)-THC-D(3)) and organic extraction. The 3 ions were ionized using positive electrospray ionization and detected in the multiple-reaction monitoring mode using mass (m)/charge (z) transitions of 318.15 > 196.20 (Delta(9)-THC-D(3)), 401.15 > 365.2 (25(OH)D(3)), and 413.15 > 355.20 (25(OH)D(2)). Reference interval study results were compared with current 25(OH)D recommendations. Elution of 25(OH)D(2), 25(OH)D(3), and Delta(9)-THC-D(3) was achieved after 3.0 minutes (total run time, 6.0 minutes). Within- and between-run coefficients of variation were less than 11%. Deming regression of radioimmunoassay and LC-MS/MS methods for total 25(OH)D levels yielded a slope of 0.97 (95% confidence interval, 0.88-1.05) and y-intercept of -1.74 ng/mL. Reference intervals were less than recommended levels (D(2), 0.0-12.1; D(3), 5.5-41.4; total vitamin D, 6.0-43.5 ng/mL [0-30, 14-103, 15-109 nmol/L, respectively]) with no statistically significant differences in race, age, or sex. This LC-MS/MS method provides a rapid, accurate, sensitive, and cost-effective alternative to other methods for detection of 25(OH)D(2) and 25(OH)D(3) at nanomolar concentrations.
血清25-羟基维生素D水平对于确定人体真正的维生素D水平很重要。本研究的目的是开发一种灵敏、特异的液相色谱-串联质谱法(LC-MS/MS)来检测25-羟基维生素D2和D3,并建立这些分析物的参考区间。在加入氘代Δ9-四氢大麻酚(D9-THC-D3)并进行有机萃取后,实现了25(OH)D2和25(OH)D3的色谱分离。这3种离子通过正电喷雾电离进行离子化,并在多反应监测模式下使用质荷比(m/z)跃迁318.15 > 196.20(D9-THC-D3)、401.15 > 365.2(25(OH)D3)和413.15 > 355.20(25(OH)D2)进行检测。将参考区间研究结果与当前25(OH)D的推荐值进行比较。25(OH)D2、25(OH)D3和D9-THC-D3在3.0分钟后洗脱(总运行时间为6.0分钟)。批内和批间变异系数均小于11%。放射免疫分析法和LC-MS/MS法对总25(OH)D水平的Deming回归得出斜率为0.97(95%置信区间,0.88 - 1.05),截距为 -1.74 ng/mL。参考区间低于推荐水平(D2,0.0 - 12.1;D3,5.5 - 41.4;总维生素D,6.0 - 43.5 ng/mL[分别为0 - 30、14 - 103、15 - 109 nmol/L]),在种族、年龄或性别方面无统计学显著差异。这种LC-MS/MS方法为检测纳摩尔浓度的25(OH)D2和25(OH)D3提供了一种快速、准确、灵敏且经济高效的替代其他方法。