晶状体间混浊:双光学与背负式人工晶状体

Interlenticular opacification: dual-optic versus piggyback intraocular lenses.

作者信息

Werner Liliana, Mamalis Nick, Stevens Scott, Hunter Brian, Chew Jesse J L, Vargas Luis G

机构信息

John A. Moran Eye Center, University of Utah, Salt Lake City, Utah 84132, USA.

出版信息

J Cataract Refract Surg. 2006 Apr;32(4):655-61. doi: 10.1016/j.jcrs.2006.01.022.

Abstract

PURPOSE

To evaluate and compare the incidence of capsular bag opacification, particularly interlenticular opacification (ILO), in rabbit eyes implanted with a dual-optic silicone intraocular lens (IOL) or piggyback lenses.

SETTING

John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.

METHODS

Ten dual-optic study IOLs (Synchrony), 10 control pairs of piggyback silicone-plate lenses, and 10 control pairs of piggyback single-piece hydrophobic acrylic lenses were implanted in the capsular bag of 30 rabbit eyes following phacoemulsification. After a 6-week follow-up, the rabbits were killed and their eyes enucleated. Anterior capsule opacification and posterior capsule opacification were graded on a 0 to 4 scale from a posterior or Miyake-Apple view. Interlenticular opacification was noted in relation to the center of the interlenticular space (periphery, paracentral, and central area) and to the number of quadrants involved. The eyes were then evaluated histopathologically.

RESULTS

Postoperative inflammatory reaction was similar in all groups. Interlenticular opacification formation was statistically different among the 3 groups of lenses (ILO extension, P = .0013, and ILO extension x ILO quadrants, P = .0023; Kruskal-Wallis test). Pairwise post comparisons of ILO formation showed that the differences between the study IOL group and the silicone-plate lens group were not significant. Interlenticular opacification post comparisons between the hydrophobic acrylic lenses and the study lens or the silicone-plate lenses were significant (P = .002 and P = .001, respectively). Histopathologic examination showed extension of the proliferating cortical material from the peripheral Soemmering's ring into the interlenticular space, causing ILO, especially with the pairs of hydrophobic acrylic lenses.

CONCLUSIONS

In this rabbit model, ILO was significantly associated with pairs of hydrophobic acrylic lenses implanted in the bag. This study appears to confirm clinical observations that implantation of 2 silicone-plate lenses in the bag is not associated with ILO. There was also a relative lack of ILO with the dual-optic silicone lens.

摘要

目的

评估并比较植入双光学面硅凝胶人工晶状体(IOL)或叠加人工晶状体的兔眼囊袋混浊,尤其是晶状体间混浊(ILO)的发生率。

设置

美国犹他州盐湖城犹他大学约翰·A·莫兰眼科中心。

方法

在30只兔眼白内障超声乳化术后,于囊袋内植入10枚双光学面研究用IOL(Synchrony)、10对对照叠加硅凝胶板状人工晶状体以及10对对照叠加单片式疏水性丙烯酸酯人工晶状体。随访6周后,处死兔子并摘除眼球。从后位或三浦-苹果视图,将前囊混浊和后囊混浊按0至4级进行分级。记录晶状体间混浊与晶状体间间隙中心(周边、旁中心和中心区域)的关系以及受累象限数量。然后对眼球进行组织病理学评估。

结果

所有组术后炎症反应相似。3组人工晶状体的晶状体间混浊形成在统计学上存在差异(ILO扩展,P = 0.0013;ILO扩展×ILO象限,P = 0.0023;Kruskal-Wallis检验)。ILO形成的两两比较显示,研究用IOL组与硅凝胶板状人工晶状体组之间的差异不显著。疏水性丙烯酸酯人工晶状体与研究用人工晶状体或硅凝胶板状人工晶状体之间的晶状体间混浊比较差异显著(分别为P = 0.002和P = 0.001)。组织病理学检查显示,增殖的皮质物质从周边的索默林环延伸至晶状体间间隙,导致ILO,尤其是在叠加疏水性丙烯酸酯人工晶状体时。

结论

在该兔模型中,ILO与囊袋内植入的疏水性丙烯酸酯人工晶状体显著相关。本研究似乎证实了临床观察结果,即囊袋内植入2枚硅凝胶板状人工晶状体与ILO无关。双光学面硅凝胶人工晶状体的ILO也相对较少。