A diffraction-intensity data-collection system with synchrotron radiation X-rays utilizing the screenless Weissenberg technique and incorporating a large-format imaging plate is one of the most suitable apparatus for time-resolved protein crystallography with larger angle oscillations than hitherto described. The time resolution and data quality of the system have been tested using a tetragonal lysozyme crystal as a test sample in a flow-cell experiment at the bending-magnet beamline 18B at the Photon Factory, and a time resolution of 15 min is confirmed.