Suppr超能文献

A new method of assessing anal sphincter integrity using inverted vectormanometry.

作者信息

Kaur Geetinder, Gardiner Angela, Duthie Graeme S

机构信息

Academic Surgical Unit, University of Hull Postgraduate Medical School, Castle Hill Hospital, Cottingham, United Kingdom.

出版信息

Dis Colon Rectum. 2006 Aug;49(8):1160-6. doi: 10.1007/s10350-006-0556-8.

Abstract

PURPOSE

Vectorgraphy as an integrated mapping of radial pressure profiles of the anal canal has been used to attempt identification of pressure-related defects with doubtful reliability since vectorgraphs bear no resemblance to endoanal ultrasound scans at similar levels in the anal canal. This study aimed to devise a technique to enable vectorgraphy to be more representative of sphincter function and integrity.

METHODS

Vectormanometry was performed in 50 patients with anorectal disorders using an Arndorfer pneumohydraulic system. "Normal" three-dimensional manometric images of each 0.5 cm of the anal sphincter were computer-generated by plotting anal pressures at rest and during squeeze radially around a central zero axis. The graphs were replotted with zero at the periphery and maximal anal pressure at the center. Both this ("inverted") and "normal" vectorgraphs were compared with endoanal ultrasound images at similar levels, assessing both internal and external anal sphincters.

RESULTS

Standard vectormanometry produced excellent pictures of pressures throughout the anal canal; the anatomy however bore no resemblance to the pictures produced by endoanal ultrasound. The inverted vectographs showed a much better correlation with endoanal ultrasound at each 0.5-mm level of the anal canal, for both squeeze pressure graphs and external sphincter correlations and for resting pressure graphs and internal sphincter correlations.

CONCLUSIONS

Accurate assessment of sphincter integrity is not possible when interpreting the vectormanometry graphs in the current format; however, inverted vectorgraphy gives good correlations with endoanal ultrasound and provides combined functional (pressure measurement) and anatomic (three-dimensional profile) information regarding the anal canal.

摘要

相似文献

1
A new method of assessing anal sphincter integrity using inverted vectormanometry.
Dis Colon Rectum. 2006 Aug;49(8):1160-6. doi: 10.1007/s10350-006-0556-8.
2
Relationship Among Anal Sphincter Injury, Patulous Anal Canal, and Anal Pressures in Patients With Anorectal Disorders.
Clin Gastroenterol Hepatol. 2015 Oct;13(10):1793-1800.e1. doi: 10.1016/j.cgh.2015.03.033. Epub 2015 Apr 11.
3
Endoanal ultrasound assessment of sphincter defects and thinning--correlation with anal manometry.
Arab J Gastroenterol. 2014 Mar;15(1):27-31. doi: 10.1016/j.ajg.2014.01.006. Epub 2014 Feb 5.
7
Anal vector volume analysis: an effective tool in the management of pelvic floor disorders.
Tech Coloproctol. 2011 Mar;15(1):31-7. doi: 10.1007/s10151-010-0658-0. Epub 2010 Dec 14.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验