Intercomparison of dosimetry systems based on CaF2:Mn TL detectors.

作者信息

Zorko B, Miljanić S, Vekić B, Stuhec M, Gobec S, Ranogajec-Komor M

机构信息

Jozef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia.

出版信息

Radiat Prot Dosimetry. 2006;119(1-4):300-5. doi: 10.1093/rpd/nci640. Epub 2006 May 30.

Abstract

The responses of readings by the TL dosimetry system MR200 TL developed in-house and used at JSI and the TOLEDO TL system used at RBI are compared. Ten measurements at different doses ranging from 0.01 mSv to 5 Sv were carried out. A set of 36 dosemeters with three pellets of CaF2:Mn were irradiated in radiation fields of 137Cs and 60Co. Analysis of the measured results shows that at doses below 0.1 Sv, readers' outputs do not differ >5% from each other. At doses >1 Sv, the results obtained by the MR200 reader must be corrected with a known factor. Finally, the reproducibility of the results from the MR200 was tested.