Suppr超能文献

数字三维摄影测量法的人体测量精度与准确性:比较Genex和3dMD成像系统以及与直接人体测量法的差异

Anthropometric precision and accuracy of digital three-dimensional photogrammetry: comparing the Genex and 3dMD imaging systems with one another and with direct anthropometry.

作者信息

Weinberg Seth M, Naidoo Sybill, Govier Daniel P, Martin Rick A, Kane Alex A, Marazita Mary L

机构信息

Center for Craniofacial and Dental Genetics, Department of Oral Medicine and Biology, School of Dental Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania 15219, USA.

出版信息

J Craniofac Surg. 2006 May;17(3):477-83. doi: 10.1097/00001665-200605000-00015.

Abstract

A variety of commercially available three-dimensional (3D) surface imaging systems are currently in use by craniofacial specialists. Little is known, however, about how measurement data generated from alternative 3D systems compare, specifically in terms of accuracy and precision. The purpose of this study was to compare anthropometric measurements obtained by way of two different digital 3D photogrammetry systems (Genex and 3dMD) as well as direct anthropometry and to evaluate intraobserver precision across these three methods. On a sample of 18 mannequin heads, 12 linear distances were measured twice by each method. A two-factor repeated measures analysis of variance was used to test simultaneously for mean differences in precision across methods. Additional descriptive statistics (e.g., technical error of measurement [TEM]) were used to quantify measurement error magnitude. Statistically significant (P < 0.05) mean differences were observed across methods for nine anthropometric variables; however, the magnitude of these differences was consistently at the submillimeter level. No significant differences were noted for precision. Moreover, the magnitude of imprecision was determined to be very small, with TEM scores well under 1 mm, and intraclass correlation coefficients ranging from 0.98 to 1. Results indicate that overall mean differences across these three methods were small enough to be of little practical importance. In terms of intraobserver precision, all methods fared equally well. This study is the first attempt to simultaneously compare 3D surface imaging systems directly with one another and with traditional anthropometry. Results suggest that craniofacial surface data obtained by way of alternative 3D photogrammetric systems can be combined or compared statistically.

摘要

目前,颅面专家正在使用各种市面上可买到的三维(3D)表面成像系统。然而,对于从其他3D系统生成的测量数据如何比较,尤其是在准确性和精密度方面,人们知之甚少。本研究的目的是比较通过两种不同的数字3D摄影测量系统(Genex和3dMD)以及直接人体测量法获得的人体测量数据,并评估这三种方法的观察者内精密度。在18个模型头部样本上,每种方法对12个线性距离进行了两次测量。采用双因素重复测量方差分析来同时检验各方法在精密度方面的平均差异。使用其他描述性统计量(如测量技术误差 [TEM])来量化测量误差大小。在九个人体测量变量上,各方法之间观察到具有统计学意义(P < 0.05)的平均差异;然而,这些差异的大小始终处于亚毫米水平。在精密度方面未观察到显著差异。此外,不精密度的大小被确定为非常小,TEM分数远低于1毫米,组内相关系数范围为0.98至1。结果表明,这三种方法之间的总体平均差异小到几乎没有实际意义。在观察者内精密度方面,所有方法表现同样良好。本研究首次尝试同时将3D表面成像系统相互直接比较,并与传统人体测量法进行比较。结果表明,通过其他3D摄影测量系统获得的颅面表面数据可以进行统计合并或比较。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验