Suppr超能文献

一种基于边缘的新计算机化头影测量标志点识别方法的有效性和可靠性。

Validity and reliability of a new edge-based computerized method for identification of cephalometric landmarks.

作者信息

Kazandjian Serge, Kiliaridis Stavros, Mavropoulos Anestis

机构信息

Department of Orthodontics, School of Dental Medicine, University of Geneva, Switzerland.

出版信息

Angle Orthod. 2006 Jul;76(4):619-24. doi: 10.1043/0003-3219(2006)076[0619:VAROAN]2.0.CO;2.

Abstract

OBJECTIVE

To evaluate the validity and inter- and intraexaminer reliability when on-screen landmarks are digitized manually or when these are computer-assisted by means of a new cephalometric software feature.

MATERIALS AND METHODS

Twenty radiographs were digitized four times by two experienced orthodontists using a manual method and an edge-based algorithm that helps landmark identification by detecting the edges of anatomical structures.

RESULTS

The computer-assisted method did not agree with manual digitization in 7 of 13 landmarks and 5 of 10 variables. With a tolerance of 0.5 mm or degrees, the two methods did not agree in cephalometric variables. Intraoperator reliability was improved for B point (x-axis), and Menton (x- and y-axis). It got worse for point A (y-axis). Interoperator reliability was improved for B point (x- and y-axis), Soft Labrale Inferior (x- and y-axis), Soft Pogonion (x-axis), and Menton (y-axis). It decreased for point A (y-axis). Intra- and interoperator reliability got better for only one cephalometric variable under study (SNB).

CONCLUSIONS

The edge-locking feature seems to be a promising tool for increasing the reliability of on-screen cephalometric analysis. There seem to be difficulties in locating the appropriate edges when artifacts or soft tissue edges are located near the targeted landmark. The existence of very small, but systematic differences between the two digitization methods manifests the need for further improvement.

摘要

目的

评估在手动数字化屏幕上的标志点时,以及借助一种新的头影测量软件功能进行计算机辅助时的有效性、检查者间和检查者内可靠性。

材料与方法

两位经验丰富的正畸医生使用手动方法和一种基于边缘的算法对20张X光片进行了四次数字化处理,该算法通过检测解剖结构的边缘来帮助标志点识别。

结果

在13个标志点中的7个以及10个变量中的5个方面,计算机辅助方法与手动数字化不一致。在头影测量变量方面,当公差为0.5毫米或度时,两种方法不一致。检查者内可靠性在B点(x轴)和颏下点(x轴和y轴)有所提高。在A点(y轴)则变差。检查者间可靠性在B点(x轴和y轴)、下唇缘点(x轴和y轴)、软组织颏前点(x轴)和颏下点(y轴)有所提高。在A点(y轴)则降低。在所研究的头影测量变量中,仅一个(SNB)的检查者内和检查者间可靠性有所提高。

结论

边缘锁定功能似乎是提高屏幕上头影测量分析可靠性的一个有前景的工具。当伪影或软组织边缘位于目标标志点附近时,在定位合适的边缘方面似乎存在困难。两种数字化方法之间存在非常小但系统的差异,这表明需要进一步改进。