Suppr超能文献

新兴实验室医嘱录入系统可用性评估的意义

The significance of a usability evaluation of an emerging laboratory order entry system.

作者信息

Peute Linda W P, Jaspers Monique W M

机构信息

Department of Medical Informatics, Academic Medical Center, University of Amsterdam, 1100 DE Amsterdam, The Netherlands.

出版信息

Int J Med Inform. 2007 Feb-Mar;76(2-3):157-68. doi: 10.1016/j.ijmedinf.2006.06.003. Epub 2006 Jul 18.

Abstract

OBJECTIVES

To assess the usability of an emerging POE system, OM/Lab, for the computer-supported ordering of laboratory tests. We were more specifically interested in the relation of the usability problems detected in the user testing sessions with the order behaviour in terms of efficiency and errors in ordering.

METHODS

A cognitive walkthrough of the OM/Lab system was conducted by two analysts using four real-life scenarios for ordering laboratory tests, which were reviewed for comprehensiveness by an expert clinician. Thereafter, the OM/Lab system was evaluated on its usability in testing sessions with seven potential end-users of the system performing these same four scenarios. The results of these end-user testing sessions were used to analyze the effect of usability flaws on the quality of ordering in terms of omissions, errors in orders and cancelled orders.

RESULTS

The analyses revealed a total of 33 usability problems, of which 25 problems were revealed both by the cognitive walkthrough and in the end-user sessions. These 25 usability problems indeed led to inefficient order behaviour, omissions and errors in orders and even to cancelled orders.

DISCUSSION

Our results revealed that the OM/Lab system suffered from a high number of usability flaws. The interface design flaws were, among other things, related to misallocation of buttons on the screen, incomprehensibility of button labels and feedback containing no relevant information to the user about the cause of errors made and consequences of a user's action. Additionally, our user test session results indicated that the OM/Lab system also suffered from user interaction problems of a more socio-technical nature. These sessions revealed, among other things, that the more specific action sequences to be executed within the ordering model of the OM/Lab system did not correspond to the daily working routines of end-users and that the grouping of laboratory tests within clusters did not match the paper-based order forms. The seemingly negative effects of these usability flaws on the quality of ordering and the inefficiency of work processes during the pilot implementation finally lead to withdrawal of the OM/Lab system from clinical practice. Though the system implementation failed, our usability study brought research on (re)designing and evaluating clinical computer applications at a higher status in our institution. It is now recognized that usability evaluation studies that will support good quality of clinical practice are highly important.

摘要

目的

评估一种新兴的电子化医嘱录入系统OM/Lab在计算机支持下进行实验室检查医嘱录入的可用性。我们特别关注在用户测试环节中发现的可用性问题与医嘱行为在效率和医嘱错误方面的关系。

方法

两名分析人员针对OM/Lab系统进行了认知走查,使用了四个用于录入实验室检查医嘱的真实场景,并由一名临床专家对其全面性进行了审核。此后,在测试环节中让该系统的七名潜在终端用户执行相同的这四个场景,以此评估OM/Lab系统的可用性。这些终端用户测试环节的结果用于分析可用性缺陷在医嘱遗漏、医嘱错误和取消医嘱方面对医嘱质量的影响。

结果

分析共发现33个可用性问题,其中25个问题在认知走查和终端用户环节中均被发现。这25个可用性问题确实导致了医嘱行为效率低下、医嘱遗漏和错误,甚至出现了取消医嘱的情况。

讨论

我们的结果表明,OM/Lab系统存在大量可用性缺陷。界面设计缺陷包括,屏幕上按钮分配不当、按钮标签难以理解以及反馈中未向用户提供有关所犯错误原因和用户操作后果的相关信息等。此外,我们的用户测试环节结果表明,OM/Lab系统还存在更多社会技术性质的用户交互问题。这些环节还表明,OM/Lab系统医嘱录入模型中要执行的更具体操作序列与终端用户的日常工作流程不相符,并且聚类中的实验室检查分组与纸质医嘱单不匹配。这些可用性缺陷对医嘱质量和试点实施期间工作流程效率产生的看似负面影响最终导致OM/Lab系统退出临床实践。尽管系统实施失败,但我们的可用性研究使我们机构中关于临床计算机应用(重新)设计和评估的研究地位得到了提升。现在人们认识到,支持临床实践高质量的可用性评估研究非常重要。