Suppr超能文献

混流泵原型的血流动力学特性:体外和急性动物实验进展报告

Hemodynamic characteristics of a mixed flow pump prototype: progress report of in vitro and acute animal experiments.

作者信息

Carrier Michel, Farinas Marie-Isabelle, Garon Andre

机构信息

Department of Surgery, Montreal Heart Institute, University of Montreal, Montreal, Quebec, Canada.

出版信息

ASAIO J. 2006 Jul-Aug;52(4):373-7. doi: 10.1097/01.mat.0000225264.27444.fa.

Abstract

A new dual-inlet mixed-flow blood pump was designed and tested in our laboratory. The objective of the present study was to analyze hemodynamic characteristics of the pump prototype in vitro and during acute in vivo experiments. The mixed-flow pump was first tested in vitro and then implanted in 11 pigs and 3 calves. The left ventricular apex was cannulated with the pump and an outflow graft was anastomosed to the descending thoracic aorta. Flow and pressure probes were also implanted. Animals were killed 3 to 12 hours after surgery. In 11 pigs, pump outflow averaged 3.8 +/- 0.4, 4.5 +/- 0.4, 5.2 +/- 0.8, 5.9 +/- 0.3, and 6.5 l/min at 8,000, 9,000, 10,000, 11,000, and 12,000 pump speed in rpm. Differential pressure at the pump averaged 45 +/- 6, 54 +/- 8, 68 +/- 16, 70 +/- 12, and 85 +/- 7 mm Hg at 8,000, 9,000, 10,000, 11,000 and 12,000 rpm. Mean aortic pressure averaged 64 +/- 15 mm Hg throughout the procedures. In 3 calves, mean aortic pressure and left ventricular pressure remained stable during 4, 6, and 9 hours of support at 9,500, 10,000, 10,500, 11,000, and 11,500 rpm. The hemodynamic performance of our mixed-flow pump appears satisfactory during short-term support in animals. It supports similarly to axial-flow blood pumps in clinical trials. Based on these findings, an ameliorated design of this mixed-flow pump running at smaller rotational speed against a similar pressure head is under way.

摘要

我们实验室设计并测试了一种新型双入口混流式血泵。本研究的目的是分析该泵原型在体外及急性体内实验中的血流动力学特性。混流式血泵首先在体外进行测试,然后植入11头猪和3头小牛体内。将泵插入左心室心尖,并将流出移植物吻合至胸降主动脉。还植入了流量和压力探头。术后3至12小时处死动物。在11头猪中,泵转速为8000、9000、10000、11000和12000转/分钟时,泵流出量平均分别为3.8±0.4、4.5±0.4、5.2±0.8、5.9±0.3和6.5升/分钟。泵处的压差在8000、9000、10000、11000和12000转/分钟时平均分别为45±6、54±8、68±16、70±12和85±7毫米汞柱。整个过程中平均主动脉压平均为64±15毫米汞柱。在3头小牛中,在9500、10000、10500、11000和11500转/分钟的支持下,4、6和9小时期间平均主动脉压和左心室压力保持稳定。我们的混流式血泵在动物短期支持期间的血流动力学性能似乎令人满意。在临床试验中,它的支持效果与轴流式血泵相似。基于这些发现,正在对这种混流式血泵进行改进设计,使其在较低转速下对抗相似的压头运行。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验