Luo Gang, Peli Eli
Schepens Eye Research Institute, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts 02114, USA.
Invest Ophthalmol Vis Sci. 2006 Sep;47(9):4152-9. doi: 10.1167/iovs.05-1672.
To study the effect of an augmented-vision device that superimposes minified contour images over natural vision on visual search performance of patients with tunnel vision.
Twelve subjects with tunnel vision searched for targets presented outside their visual fields (VFs) on a blank background under three cue conditions (with contour cues provided by the device, with auditory cues, and without cues). Three subjects (VF, 8 degrees -11 degrees wide) carried out the search over a 90 degrees x 74 degrees area, and nine subjects (VF, 7 degrees -16 degrees wide) carried out the search over a 66 degrees x 52 degrees area. Eye and head movements were recorded for performance analyses that included directness of search path, search time, and gaze speed.
Directness of the search path was greatly and significantly improved when the contour or auditory cues were provided in the larger and the smaller area searches. When using the device, a significant reduction in search time (28% approximately 74%) was demonstrated by all three subjects in the larger area search and by subjects with VFs wider than 10 degrees in the smaller area search (average, 22%). Directness and gaze speed accounted for 90% of the variability of search time.
Although performance improvement with the device for the larger search area was obvious, whether it was helpful for the smaller search area depended on VF and gaze speed. Because improvement in directness was demonstrated, increased gaze speed, which could result from further training and adaptation to the device, might enable patients with small VFs to benefit from the device for visual search tasks.
研究一种增强视觉设备,该设备将缩小的轮廓图像叠加在自然视觉上,对管状视野患者视觉搜索性能的影响。
12名管状视野患者在三种提示条件下(由该设备提供轮廓提示、听觉提示和无提示),在空白背景上搜索呈现于其视野(VF)之外的目标。3名患者(VF,宽8度 - 11度)在90度×74度区域内进行搜索,9名患者(VF,宽7度 - 16度)在66度×52度区域内进行搜索。记录眼睛和头部运动以进行性能分析,包括搜索路径的直接性、搜索时间和注视速度。
在较大和较小区域搜索中提供轮廓或听觉提示时,搜索路径的直接性得到极大且显著的改善。使用该设备时,在较大区域搜索中,所有3名患者以及在较小区域搜索中VF宽于10度的患者(平均22%)的搜索时间均显著减少(28%至74%)。直接性和注视速度占搜索时间变异性的90%。
尽管该设备在较大搜索区域的性能改善明显,但它对较小搜索区域是否有帮助取决于VF和注视速度。由于证明了直接性有所改善,通过进一步训练和适应该设备可能导致的注视速度增加,可能使小VF患者从该设备用于视觉搜索任务中受益。