Suppr超能文献

采用同位素稀释气相色谱/质谱联用技术并结合先前的自动固相萃取法分析西班牙地表水中的农药和代谢物 分析结果不确定度的评估

Analysis of pesticides and metabolites in Spanish surface waters by isotope dilution gas chromatography/mass spectrometry with previous automated solid-phase extraction Estimation of the uncertainty of the analytical results.

作者信息

Planas Carles, Puig Alejandra, Rivera Josep, Caixach Josep

机构信息

Mass Spectrometry Laboratory, Department of Ecotechnologies, IIQAB-CSIC, C/Jordi Girona 18-26, 08034 Barcelona, Spain.

出版信息

J Chromatogr A. 2006 Oct 27;1131(1-2):242-52. doi: 10.1016/j.chroma.2006.07.091. Epub 2006 Sep 8.

Abstract

A method based on isotope dilution gas chromatography/mass spectrometry (GC/MS) with automated solid-phase extraction (SPE) is described for the analysis of 32 pesticides and metabolites in surface waters. This approach consist in the use of nine isotopically labelled representative pesticides as internal standards, which allows high accuracy (trueness and precision) and sensitivity for most analysed compounds, as it is required for isotope dilution-based methods. Uncertainties associated with pesticide determination in real samples were estimated using quality assurance/quality control (QA/QC) data. For most pesticides expanded uncertainty was below 40%, according to the commonly established requirements for analytical results. Ninety three Spanish surface waters collected in June-July and September-November 2004 were analysed. Concentration and occurrence of pesticides were evaluated. These parameters were higher in the summer than in the autumn period. In summer four pesticides were found in more than 50% of the analysed samples and four compounds were detected above the concentration level of 1 microg/l (atrazine, terbutylazine, 3,4-dichloroaniline and fenitrothion), while in autumn percentage of detection was below 50% for all pesticides and only one compound (terbutylazine) exceeded 1 microg/l.

摘要

描述了一种基于同位素稀释气相色谱/质谱联用(GC/MS)和自动固相萃取(SPE)的方法,用于分析地表水中的32种农药及其代谢物。该方法使用9种同位素标记的代表性农药作为内标,对于大多数分析化合物而言,这能实现高精度(准确性和精密度)和高灵敏度,这是基于同位素稀释的方法所要求的。利用质量保证/质量控制(QA/QC)数据估算实际样品中农药测定的不确定度。根据分析结果的常用既定要求,大多数农药的扩展不确定度低于40%。对2004年6 - 7月和9 - 11月采集的93份西班牙地表水进行了分析。评估了农药的浓度和检出情况。这些参数夏季高于秋季。夏季,在超过50%的分析样品中发现了4种农药,4种化合物的检测浓度高于1微克/升(莠去津、特丁津、3,4 - 二氯苯胺和杀螟硫磷),而秋季所有农药的检出率均低于50%,只有一种化合物(特丁津)超过1微克/升。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验