A portable amperometric potentiostat was designed and implemented in this work. It was developed to acquisit the current signals produced from bilirubin by an electrochemical sensor. Based on an SOC-based chip, this potentiostat has the merits of moderate accuracy, small size, low cost, and high portability. The bilirubin electrode was prepared by synthesizing a thin layer of bilirubin imprinted poly(methacrylic acid-co-ethylene glycol dimethacrylate) onto the Au layer. With the molecularly imprinted polymer (MIP) film, specific detection of bilirubin was successfully achieved. The cyclic voltammogram of the electrode was measured from this assembled potentiostat. The performance from a commercial potentiostat was considered rather stable and was used as a reference to examine and evaluate the performance of the assembled potentiostat. The detected current signals by the bilirubin sensing were obtained. Linear calibration with a sensitivity of 1.344+/-0.38 microA/mg dl was achieved. Our experimental results showed that the proposed potentiostat's performance could achieve sufficient performance. The evaluation was also made from the aspects such as reset time and steady-response time. The self-assembled potentiostat thus demonstrated its ability in precise detection of bilirubin from an electrode layered with the imprinted polymer film.
在本工作中设计并实现了一种便携式安培电位滴定仪。它被开发用于采集电化学传感器产生的胆红素电流信号。基于一款基于片上系统(SOC)的芯片,该电位滴定仪具有精度适中、体积小、成本低和便携性高的优点。胆红素电极是通过在金层上合成一层胆红素印迹聚(甲基丙烯酸 - 乙二醇二甲基丙烯酸酯)来制备的。借助分子印迹聚合物(MIP)膜,成功实现了对胆红素的特异性检测。从组装好的电位滴定仪测量该电极的循环伏安图。一款商用电位滴定仪的性能被认为相当稳定,并被用作参考来检验和评估组装电位滴定仪的性能。获得了通过胆红素传感检测到的电流信号。实现了灵敏度为1.344±0.38微安/毫克·分升的线性校准。我们的实验结果表明,所提出的电位滴定仪的性能可以达到足够的水平。还从复位时间和稳态响应时间等方面进行了评估。因此,自组装电位滴定仪展示了其从涂覆有印迹聚合物膜的电极中精确检测胆红素的能力。