Suppr超能文献

Histologic evaluation of implants following flapless and flapped surgery: a study in canines.

作者信息

Becker William, Wikesjö Ulf M E, Sennerby Lars, Qahash Mohammed, Hujoel Philippe, Goldstein Moshe, Turkyilmaz Ilser

机构信息

University of Southern California School of Dentistry, Los Angeles, CA, USA.

出版信息

J Periodontol. 2006 Oct;77(10):1717-22. doi: 10.1902/jop.2006.060090.

Abstract

BACKGROUND

Flapless surgery requires penetration of the alveolar mucosa and bone without reflection of mucoperiosteal flaps. Do these techniques force gingival tissue or foreign materials into osteotomies? If so, do such tissues or materials interfere with osseointegration? A proof-of-principle study using a canine model attempted to answer these questions.

METHODS

Five young adult Hound Labrador mongrel dogs received implants with a moderately roughened surface by anodic oxidation using flapless or conventional one-stage (control) surgery in contralateral jaw quadrants. The implants were placed into the osteotomies, and the international stability quotient (ISQ) was recorded using resonance frequency analysis. These measurements were repeated following a 3-month healing interval when the animals were euthanized, and implants and surrounding tissues were retrieved and processed for histologic analysis.

RESULTS

The implants were stable upon insertion and demonstrated increased stability at 3 months without significant differences between surgical protocols. The histologic evaluation showed high bone-implant contact (flapless surgery: 54.7% +/- 8.4%; control: 52.2% +/- 13.0%; P >0.05) without evidence of gingival tissue or foreign body inclusions. There were no significant differences in marginal bone levels between the surgical protocols. Post-insertion and at 3 months, ISQ values depended on the amount of torque delivered. Immediately post-insertion, for every 1-unit increase in torque value, the ISQ increased by 0.3 (95% confidence interval: 0.1 to 0.4; P = 0.0043). Three months postoperatively, for every one-unit increase in torque the ISQ value decreased 0.2 (95% confidence interval: -0.4 to -0.1; P = 0.0012). The effect of torque on ISQ values was independent of treatment effects and remained significant after adjustment for treatment.

CONCLUSIONS

The results suggest that implants placed without flap reflection remain stable and exhibit clinically relevant osseointegration similar to when implants are placed with flapped procedures. Greater torque at implant placement resulted in less implant stability at 3 months.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验