The equilibrated Kt/V (eKt/V), a clinical index of hemodialysis adequacy, can be calculated by several means. The commonly used methods are second generation of natural logarithm by Daugirdas and rate adjustment methods. However these two methods used immediate post-dialysis blood urea nitrogen (BUN) (C0). The authors investigated the accuracy of 30-minute post-dialysis BUN (C30), equilibrated BUN at the end of urea rebound time, to determine the eKt/V MATERIAL AND METHOD: We measured 7 values of eKt/V in 30 hemodialysis sessions by using the 5 following methods: 1). Empirical method (Emp) 2). Smye method (Sm) 3). Daugirdas method using C0 and C30 (Dau0, Dau30) 4). Rate adjustment method using C0 and C30 (Rate0, Rate30) 5). Double Pool urea kinetic model (DP), and compared with the gold standard values calculated by the modified Direct Dialysate Quantitative method (mDDQ).
All patients had adequate hemodialysis with eKt/V (mDDQ) = 1.80 + 0.22. Compared with mDDQ, the median of absolute difference of eKt/V were Rate30 (0.10); Dau30 (0.11), Rate0 (0.11), Sm (0.11); Emp (0.13); DP (0.15); Dau0 (0.35) while the correlation coefficient (r2) were 0.926, 0.948, 0.785, 0.629, 0.551, 0.833,and 0.806 respectively.
By using 30-minute post-dialysis BUN to calculate, the values of eKt/V by Daugirdas and rate adjustment methods were associated with better accuracy and correlation than immediate post-dialysis BUN. In the demand of the accurate eKt/V measurement, the Dau30 and Rate30 may be the suitable method to determine the eKt/V in clinical hemodialysis.
平衡Kt/V(eKt/V)作为血液透析充分性的临床指标,可通过多种方法计算得出。常用方法有Daugirdas第二代自然对数法和速率调整法。然而,这两种方法均使用透析后即刻血尿素氮(BUN)(C0)。作者研究了透析后30分钟BUN(C30),即尿素反弹期末的平衡BUN,用于确定eKt/V的准确性。
我们在30次血液透析治疗中,采用以下5种方法测量了7个eKt/V值:1)经验法(Emp);2)Smye法(Sm);3)使用C0和C30的Daugirdas法(Dau0、Dau30);4)使用C0和C30的速率调整法(Rate0、Rate30);5)双池尿素动力学模型(DP),并与改良直接透析液定量法(mDDQ)计算的金标准值进行比较。
所有患者血液透析充分,eKt/V(mDDQ)=1.80±0.22。与mDDQ相比,eKt/V绝对差值的中位数分别为:Rate30(0.10);Dau30(0.11),Rate0(0.11),Sm(0.11);Emp(0.13);DP(0.15);Dau0(0.35),而相关系数(r2)分别为0.926、0.948、0.785、0.629、0.551、0.833和0.806。
通过使用透析后30分钟BUN进行计算,Daugirdas法和速率调整法得出的eKt/V值比透析后即刻BUN具有更高的准确性和相关性。在需要精确测量eKt/V的情况下,Dau30和Rate30可能是临床血液透析中确定eKt/V的合适方法。