Wilcock Andrew, Jacob Jayin K, Charlesworth Sarah, Harris Elayne, Gibbs Margaret, Allsop Helen
University of Nottingham, Nottingham, UK.
Palliat Med. 2006 Oct;20(7):661-4. doi: 10.1177/0269216306070755.
The use of a syringe driver to administer drugs by continuous subcutaneous infusion is common practice in the UK. Over time, drug combinations used in a syringe driver are likely to change and the aim of this survey was to obtain a more recent snapshot of practice. On four separate days, at two-week intervals, a questionnaire was completed for every syringe driver in use by 15 palliative care services. Of 336 syringe drivers, the majority contained either two or three drugs, but one-fifth contained only one drug. The median (range) volume of the infusions was 15 (9.5-48) mL, and duration of infusion was generally 24 hours. Only one combination was reported as visually incompatible, and there were 13 site reactions (4% of total). Laboratory physical and chemical compatibility data are available for less than half of the most frequently used combinations.
在英国,使用注射器泵通过皮下持续输注给药是常见的做法。随着时间的推移,注射器泵中使用的药物组合可能会发生变化,本次调查的目的是获取更近期的实践情况。在四个不同的日子里,每隔两周,为15家姑息治疗服务机构正在使用的每个注射器泵填写一份问卷。在336个注射器泵中,大多数含有两种或三种药物,但五分之一仅含有一种药物。输注的中位数(范围)体积为15(9.5 - 48)mL,输注持续时间通常为24小时。仅有一种组合被报告为视觉上不相容,有13例局部反应(占总数的4%)。对于最常用组合中不到一半的组合,可获得实验室物理和化学相容性数据。