Suppr超能文献

使用[15O]H2O和正电子发射断层扫描同时评估心肌血流量、心脏功能和肺含水量。

Simultaneous evaluation of myocardial blood flow, cardiac function and lung water content using [15O]H2O and positron emission tomography.

作者信息

Naum Alexandru, Tuunanen Helena, Engblom Erik, Oikonen Vesa, Sipilä Hannu, Iozzo Patricia, Nuutila Pirjo, Knuuti Juhani

机构信息

Turku PET Centre, Turku University Central Hospital, P.O. Box 52, 20521, Turku, Finland.

出版信息

Eur J Nucl Med Mol Imaging. 2007 Apr;34(4):563-72. doi: 10.1007/s00259-006-0259-3. Epub 2006 Oct 24.

Abstract

PURPOSE

This study sought to evaluate an imaging approach using [15O]H2O and positron emission tomography (PET) for simultaneous assessment of myocardial perfusion, cardiac function and lung water content as a potential indicator of pulmonary oedema.

METHODS

Twenty-six subjects divided into two groups (group I, 13 patients with idiopathic dilated cardiomyopathy; group II, 13 healthy volunteers) underwent dynamic PET scanning after intravenous infusion of approximately 995 MBq [15O]H2O. In both groups, echocardiograms were performed after the PET studies. From the dynamic [15O]H2O data, lung water content (LWC) at equilibrium, myocardial blood flow (MBF), cardiac output (CO), stroke volume (SV) and stroke volume indexes (SVI) using the indicator dilution principle were determined.

RESULTS

LWC was 18% (p = 0.038) higher in patients than in controls. Global MBF did not differ significantly between the groups, but regional MBF values were significantly lower (p < 0.05) in the anterior and septal walls in the patient group. The results of the Passing-Bablok regression indicated the absence of a systematic difference between the two techniques. Bland-Altman analysis performed for each group (patients vs healthy controls) showed a non-significant bias (p > 0.1) of -0.02 +/- 0.82 vs -0.05 +/- 0.54 l/min (CO), -1.44 +/- 14.31 vs 1.70 +/- 10.56 ml/beat (SV) and 0.47 +/- 6.21 vs 0.30 +/- 5.02 ml/beat/m2 (SVI). The 95% limits of agreement were -1.62 to 1.59 vs -1.11 to 1.01 l/min (CO), -26.61 to 29.49 vs -22.39 to 18.99 ml/beat (SV) and -11.69 to 12.88 vs -9.53 to 10.14 ml/beat/m2 (SVI). Right ventricular CO was increased by 33% (p = 0.014) in the patient group as compared with normal controls.

CONCLUSION

Our results demonstrate that additional analysis of cardiac function and lung water content are feasible from the dynamic cardiac [15O]H2O PET studies acquired for myocardial perfusion. The parameters appear to work as expected. Further studies are warranted to elucidate the clinical value of these new parameters.

摘要

目的

本研究旨在评估一种使用[15O]H2O和正电子发射断层扫描(PET)的成像方法,用于同时评估心肌灌注、心功能和肺含水量,作为肺水肿的潜在指标。

方法

26名受试者分为两组(第一组,13例特发性扩张型心肌病患者;第二组,13名健康志愿者),在静脉输注约995 MBq [15O]H2O后进行动态PET扫描。两组在PET研究后均进行了超声心动图检查。根据动态[15O]H2O数据,使用指示剂稀释原理测定平衡时的肺含水量(LWC)、心肌血流量(MBF)、心输出量(CO)、每搏输出量(SV)和每搏输出量指数(SVI)。

结果

患者的LWC比对照组高18%(p = 0.038)。两组间整体MBF无显著差异,但患者组前壁和室间隔的局部MBF值显著较低(p < 0.05)。Passing-Bablok回归结果表明两种技术之间不存在系统差异。对每组(患者与健康对照)进行的Bland-Altman分析显示,CO的偏差不显著(p > 0.1),分别为-0.02±0.82与-0.05±0.54 l/min;SV为-1.44±14.31与1.70±10.56 ml/次搏动;SVI为0.47±6.21与0.30±5.02 ml/次搏动/m2。一致性界限的95%分别为-1.62至1.59与-1.11至1.01 l/min(CO);-26.61至29.49与-22.39至18.99 ml/次搏动(SV);-11.69至12.88与-9.53至10.14 ml/次搏动/m2(SVI)。与正常对照组相比,患者组右心室CO增加了33%(p = 0.014)。

结论

我们的结果表明,从用于心肌灌注的动态心脏[15O]H2O PET研究中对心功能和肺含水量进行额外分析是可行的。这些参数似乎按预期发挥作用。有必要进一步研究以阐明这些新参数的临床价值。