Suppr超能文献

串联提供阻力的隐形眼镜下计算得出的泪液氧张力:背驮式和巩膜镜。

Calculated tear oxygen tension under contact lenses offering resistance in series: piggyback and scleral lenses.

作者信息

Weissman Barry A, Ye Ping

机构信息

Jules Stein Eye Institute and Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095-7003, USA.

出版信息

Cont Lens Anterior Eye. 2006 Dec;29(5):231-7. doi: 10.1016/j.clae.2006.09.001. Epub 2006 Oct 24.

Abstract

BACKGROUND

Models of oxygen delivery to the cornea with contact lens wear have considered the customary situation of one lens being worn on the cornea. However, two lenses, such as a rigid lens piggybacked on a soft lens, may be worn by patients with special ocular and visual needs. This paper extends existing single lens models to circumstances where two lenses offer resistance to oxygen in series.

METHODS

Theoretical oxygen tensions are calculated for tear layers trapped beneath piggyback contact lens systems (and scleral lenses) and the anterior corneal surface with a simple single chamber corneal model using a personal computer software spreadsheet.

RESULTS

Acceptable values are anticipated for contact lens materials of modern oxygen permeability values of approximately 60-100 Fatt Dk units under open eye conditions.

CONCLUSIONS

The results of this spreadsheet model of oxygen supply to the anterior corneal surface offer a useful guide to clinicians concerned about providing their patients with physiologically acceptable piggyback lens systems.

摘要

背景

佩戴隐形眼镜时角膜氧气供应模型考虑的是角膜上佩戴一片镜片的常规情况。然而,有特殊眼部和视觉需求的患者可能会佩戴两片镜片,比如在软性镜片上背负一片硬性镜片。本文将现有的单镜片模型扩展至两片镜片串联对氧气产生阻力的情况。

方法

使用个人电脑软件电子表格,通过一个简单的单腔角膜模型计算背负式隐形眼镜系统(以及巩膜镜)下方和角膜前表面截留的泪液层的理论氧分压。

结果

在睁眼条件下,对于现代氧透系数约为60 - 100法特Dk单位的隐形眼镜材料,预期可得到可接受的值。

结论

该电子表格模型得出的角膜前表面氧气供应结果,为关心为患者提供生理上可接受的背负式镜片系统的临床医生提供了有用的指导。