Tahamiler Rauf, Edizer Deniz Tuna, Canakcioglu Salih, Guvenc Melih Guven, Inci Ender, Dirican Ahmet
Otorhinolaryngology Department, Istanbul University, Cerrahpasa Medical School, Istanbul, Turkey.
Laryngoscope. 2006 Nov;116(11):2050-4. doi: 10.1097/01.mlg.0000240173.74885.0d.
Current measurements of nasal obstruction are unreliable and may be improved with the development of new techniques. The effectiveness of odiosoft-rhino (OR) in the evaluation of nasal obstruction was investigated in a blind comparison at a referral center, institutional practice.
Forty-eight patients with perennial allergic rhinitis and 52 healthy subjects were studied. Nasal endoscopic examination, acoustic rhinometry (AR), and OR were performed and symptom scores compared.
Assessment of nasal blockage with OR method was the main outcome measure.
Using the OR technique, significant differences were observed between the patient and control groups. OR data correlated with symptom scores and endoscopic examination. However, this was not observed with AR. A 15.5-dB cutoff point for the left side and 14.5 dB cutoff point for the right side at the 2,000 to 4,000 Hz frequency interval resulted in 93.8% sensitivity and 92.3% specificity and 72.9% sensitivity and 80.8% specificity, respectively. A 8.5-dB cutoff point for the left and right sides at the 4,000 to 6,000 Hz frequency interval resulted in 87.5% sensitivity and 80.8% specificity and 70.8% sensitivity and 78.8% specificity, respectively.
OR is a simple, noninvasive test for assessing nasal obstruction. The OR technique can detect nasal obstruction with high sensitivity and specificity, and these findings correlate with symptoms and physical examination.
目前对鼻阻塞的测量方法不可靠,新技术的发展可能会有所改善。在一家转诊中心的机构实践中,通过盲法比较研究了odiosoft - rhino(OR)在评估鼻阻塞方面的有效性。
对48例常年性变应性鼻炎患者和52例健康受试者进行了研究。进行了鼻内镜检查、鼻声反射(AR)和OR检查,并比较了症状评分。
采用OR方法评估鼻阻塞情况是主要观察指标。
使用OR技术,在患者组和对照组之间观察到显著差异。OR数据与症状评分和内镜检查相关。然而,AR未观察到这种情况。在2000至4000Hz频率区间,左侧15.5dB的截断点和右侧14.5dB的截断点分别产生了93.8%的灵敏度和92.3%的特异度,以及72.9%的灵敏度和80.8%的特异度。在4000至6000Hz频率区间,左右两侧8.5dB的截断点分别产生了87.5%的灵敏度和80.8%的特异度,以及70.8%的灵敏度和78.8%的特异度。
OR是一种评估鼻阻塞的简单、非侵入性检查。OR技术能够以高灵敏度和特异度检测鼻阻塞,且这些结果与症状和体格检查相关。