A new biofidelity assessment system is being developed and applied to three side impact dummies: the WorldSID-alpha, the ES-2 and the SID-HIII. This system quantifies (1) the ability of a dummy to load a vehicle as a cadaver does, "External Biofidelity," and (2) the ability of a dummy to replicate those cadaver responses that best predict injury potential, "Internal Biofidelity." The ranking system uses cadaver and dummy responses from head drop tests, thorax and shoulder pendulum tests, and whole body sled tests. Each test condition is assigned a weight factor based on the number of human subjects tested to form the biomechanical response corridor and how well the biofidelity tests represent FMVSS 214, side NCAP (SNCAP) and FMVSS 201 Pole crash environments. For each response requirement, the cumulative variance of the dummy response relative to the mean cadaver response (DCV) and the cumulative variance of the mean cadaver response relative to the mean plus one standard deviation (CCV) are calculated. The ratio of DCV/CCV expresses how well the dummy response duplicates the mean cadaver response: a smaller ratio indicating better biofidelity. For each test condition, the square root is taken of each Response Comparison Value (DCV/CCV), and then these values are averaged and multiplied by the appropriate Test Condition Weight. The weighted and averaged comparison values are then summed and divided by the sum of the Test Condition Weights to obtain a rank for each body region. Each dummy obtains an overall rank for External Biofidelity and an overall rank for Internal Biofidelity comprised of an average of the ranks from each body region. Of the three dummies studied, the selected comparison test data indicate that the WorldSID-alpha prototype dummy demonstrated the best overall External Biofidelity although improvement is needed in all of the dummies to better replicate human kinematics. All three dummies estimate potential injury assessment with similar levels of Internal Biofidelity.

摘要

一种新的生物逼真度评估系统正在开发中,并应用于三种侧面碰撞假人:WorldSID-alpha、ES-2和SID-HIII。该系统量化了(1)假人像尸体一样加载车辆的能力,即“外部生物逼真度”,以及(2)假人复制那些最能预测损伤可能性的尸体反应的能力,即“内部生物逼真度”。排名系统使用了头部跌落试验、胸部和肩部摆锤试验以及全身滑车试验中的尸体和假人反应。根据测试的人体受试者数量、形成生物力学反应走廊的情况以及生物逼真度测试对FMVSS 214、侧面新车评估程序(SNCAP)和FMVSS 201柱碰撞环境的代表程度,为每个测试条件分配一个权重因子。对于每个反应要求,计算假人反应相对于平均尸体反应的累积方差(DCV)以及平均尸体反应相对于均值加一个标准差的累积方差(CCV)。DCV/CCV的比值表示假人反应复制平均尸体反应的程度:比值越小,生物逼真度越高。对于每个测试条件,取每个反应比较值(DCV/CCV)的平方根,然后将这些值平均并乘以适当的测试条件权重。然后将加权和平均后的比较值相加,并除以测试条件权重的总和,以获得每个身体区域的排名。每个假人获得外部生物逼真度的总体排名和内部生物逼真度的总体排名,内部生物逼真度的总体排名由每个身体区域的排名平均值组成。在所研究的三个假人中,选定的比较测试数据表明,尽管所有假人都需要改进以更好地复制人体运动学,但WorldSID-alpha原型假人展示出了最佳的总体外部生物逼真度。所有三个假人在内部生物逼真度水平相似的情况下估计潜在损伤评估。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验