Lee Yong-Keun, Powers John M
Department of Dental Biomaterials Science, Dental Research Institute, College of Dentistry, Seoul National University, Jongro-gu, Seoul, Korea.
J Mater Sci Mater Med. 2007 May;18(5):685-91. doi: 10.1007/s10856-006-0011-3. Epub 2006 Nov 30.
The objective was to measure the combined effect of mucin, chlorhexidine and tea solution on the staining of four dental resin composites, and to determine the effect of surface sealant on staining. One side of cured resin composite specimens of 10 mm in diameter and 2 mm in thickness were polished with 600-grit silicon carbide paper. One group of specimens (n = 5) was treated with a surface sealant [BisCover, Bisco, USA; SS (surface sealant) group], and the other group was not (NO group; control). Specimens were sequentially immersed in the following substances: Mucin in phosphate buffered saline (PBS); chlorhexidine; tea solution; and ultrasonic cleaning and then immersion in PBS. Color was measured on a reflection spectrophotometer. Changes in color (DeltaE () (ab)) and color parameters, such as hue, chroma and value, after immersion in tea solution and subsequent cleaning were analyzed by repeated measures, analysis of variance at the 0.05 level of significance. The range of DeltaE () (ab) values after immersion in tea solution was 11.4-21.1 for NO group and 10.5-19.6 for SS group, and that after cleaning was 2.4-10.0 for NO group and 2.7-8.3 for SS group. After staining, CIE L () value (lightness) decreased, and CIE a () and b () values increased. Color changes of resin composites were not acceptable after sequential immersion treatment (DeltaE () ( ab ) > 3.3). The changes in color and color parameters of sealant applied group were not significantly different from those of control group except for a few combinations of color parameters and resin composites.
目的是测量黏蛋白、氯己定和茶溶液对四种牙科树脂复合材料染色的综合影响,并确定表面封闭剂对染色的影响。将直径10毫米、厚度2毫米的固化树脂复合材料试样的一侧用600目碳化硅纸抛光。一组试样(n = 5)用表面封闭剂[BisCover,Bisco,美国;SS(表面封闭剂)组]处理,另一组不处理(NO组;对照组)。试样依次浸入以下物质中:磷酸盐缓冲盐水(PBS)中的黏蛋白;氯己定;茶溶液;进行超声清洗,然后浸入PBS中。用反射分光光度计测量颜色。在0.05显著性水平下,通过重复测量方差分析,分析浸入茶溶液及随后清洗后颜色变化(ΔE*(ab))和颜色参数,如色调、彩度和明度。NO组浸入茶溶液后的ΔE*(ab)值范围为11.4 - 21.1,SS组为10.5 - 19.6;清洗后的范围,NO组为2.4 - 10.0,SS组为2.7 - 8.3。染色后,CIE L值(明度)降低,CIE a和b值升高。顺序浸入处理后树脂复合材料的颜色变化不可接受(ΔE(ab)> 3.3)。除了少数颜色参数和树脂复合材料的组合外,应用封闭剂组的颜色和颜色参数变化与对照组无显著差异。