使用“嗅觉棒”进行嗅觉功能测试的标准值。

Normative values of olfactory function testing using the 'sniffin' sticks'.

作者信息

Katotomichelakis Michael, Balatsouras Dimitrios, Tripsianis Gregori, Tsaroucha Aleka, Homsioglou Elias, Danielides Vassilios

机构信息

Department of Otolaryngology, Medical School, Democritus University of Thrace, Alexandroupolis, Greece.

出版信息

Laryngoscope. 2007 Jan;117(1):114-20. doi: 10.1097/01.mlg.0000246518.79894.7e.

Abstract

OBJECTIVES

Quantitative olfactory assessment is often neglected in clinical practice, although olfactory loss can assist to diagnosis and may lead to significant morbidity. "Sniffin' Sticks" is a modern test of nasal chemosensory performance that is based on penlike odor-dispensing devices. It consists of three tests of olfactory function: odor threshold, odor discrimination, and odor identification. The results of this test may be presented as a composite threshold-discrimination-identification (TDI) score. The aim of this study was first to develop normative data of olfactory function for the Greek population using this test and second to relate olfactory performance to age, sex, and side examined.

STUDY DESIGN

The authors conducted a prospective clinical trial.

METHODS

A total of 93 healthy subjects were included in the study, 48 males and 45 females, mean age of 44.5 years (range, 6-84 years).

RESULTS

A database of normal values for olfactory testing was established for the Greek population. Females performed better than males and older subjects performed less efficiently in all tests. We also found a right nostril advantage compared with the left. Additionally, scores obtained from bilateral presentation were similar with scores obtained from the nostril with the better performance.

CONCLUSIONS

The "Sniffin' Sticks" can be used effectively in the Greek population to evaluate olfactory performance. Mean values of olfactory tests obtained were better in comparison with data from settings located in central and northern Europe.

摘要

目的

嗅觉定量评估在临床实践中常被忽视,尽管嗅觉丧失有助于诊断且可能导致严重的发病率。“嗅觉棒”是一种基于笔状气味散发装置的现代鼻化学感觉功能测试。它由三项嗅觉功能测试组成:气味阈值、气味辨别和气味识别。该测试结果可呈现为综合阈值 - 辨别 - 识别(TDI)分数。本研究的目的首先是使用该测试为希腊人群建立嗅觉功能的规范数据,其次是将嗅觉表现与年龄、性别及检查的鼻腔侧别相关联。

研究设计

作者进行了一项前瞻性临床试验。

方法

共有93名健康受试者纳入研究,其中48名男性和45名女性,平均年龄44.5岁(范围6 - 84岁)。

结果

为希腊人群建立了嗅觉测试正常值数据库。在所有测试中,女性表现优于男性,年龄较大的受试者表现较差。我们还发现右侧鼻孔比左侧有优势。此外,双侧测试获得的分数与表现较好的鼻孔测试获得的分数相似。

结论

“嗅觉棒”可有效用于希腊人群评估嗅觉表现。与来自欧洲中部和北部地区的数据相比,所获得的嗅觉测试平均值更好。