Pai Balaji S, Varma Ravi G, Kulkarni Raghavendra N, Nirmala S, Manjunath L C, Rakshith S
Department of Neurosurgery, MS Ramaiah Medical College, Bangalore - 560 085, India.
Neurol India. 2007 Jan-Mar;55(1):31-41. doi: 10.4103/0028-3886.30424.
The microsurgical anatomy of the posterior circulation is very complex and variable. Surgical approaches to this area are considered risky due to the presence of the various important blood vessels and neural structures.
To document the microsurgical anatomy of the posterior circulation along with variations in the Indian population.
The authors studied 25 cadaveric brain specimens. Microsurgical dissection was carried out from the vertebral arteries to the basilar artery and its branches, the basilar artery bifurcation, posterior cerebral artery and its various branches. Measurements of the outer diameters of the vertebral artery, basilar artery and posterior cerebral artery and their lengths were taken.
The mean diameter of the vertebral artery was 3.4 mm on the left and 2.9 mm on the right. The diameter of the basilar artery varied from 3-7 mm (mean of 4.3 mm). The length varied from 24-35 mm (mean of 24.9 mm). The basilar artery gave off paramedian and circumferential perforating arteries. The origin of the anterior inferior cerebellar artery (AICA) varied from 0-21 mm (mean 10.0 mm) from the vertebrobasilar junction. The diameter of the AICA varied from being hypoplastic i.e.,
The authors have documented the various anomalies as well as the differences of the anatomy in this area in the Indian population as compared to the Western literature.
后循环的显微外科解剖结构非常复杂且多变。由于存在各种重要血管和神经结构,该区域的手术入路被认为具有风险。
记录后循环的显微外科解剖结构以及印度人群中的变异情况。
作者研究了25个尸体脑标本。从椎动脉至基底动脉及其分支、基底动脉分叉、大脑后动脉及其各分支进行显微解剖。测量了椎动脉、基底动脉和大脑后动脉的外径及其长度。
椎动脉平均直径左侧为3.4mm,右侧为2.9mm。基底动脉直径在3 - 7mm之间变化(平均4.3mm)。长度在24 - 35mm之间变化(平均24.9mm)。基底动脉发出旁正中动脉和环行穿动脉。小脑前下动脉(AICA)的起源距椎基底动脉交界处0 - 21mm(平均10.0mm)。AICA的直径变化范围从发育不全即
与西方文献相比,作者记录了印度人群中该区域的各种异常以及解剖结构差异。