扫描透射X射线显微镜中的定量振幅和相衬成像。

Quantitative amplitude and phase contrast imaging in a scanning transmission X-ray microscope.

作者信息

Hornberger Benjamin, Feser Michael, Jacobsen Chris

机构信息

Department of Physics and Astronomy, Stony Brook University, Stony Brook, NY 11794-3800, USA.

出版信息

Ultramicroscopy. 2007 Aug;107(8):644-55. doi: 10.1016/j.ultramic.2006.12.006. Epub 2007 Jan 8.

Abstract

Phase contrast in X-ray imaging provides lower radiation dose, and dramatically higher contrast at multi-keV photon energies when compared with absorption contrast. We describe here the use of a segmented detector in a scanning transmission X-ray microscope to collect partially coherent bright field images. We have adapted a Fourier filter reconstruction technique developed by McCallum, Landauer and Rodenburg to retrieve separate, quantitative maps of specimen phase shift and absorption. This is demonstrated in the imaging of a germanium test pattern using 525eV soft X-rays.

摘要

与吸收对比度相比,X射线成像中的相衬成像可提供更低的辐射剂量,并且在多keV光子能量下具有显著更高的对比度。我们在此描述了在扫描透射X射线显微镜中使用分段探测器来收集部分相干明场图像。我们采用了由麦卡勒姆、兰道尔和罗登伯格开发的傅里叶滤波重建技术,以获取样品相移和吸收的单独定量图谱。这在使用525eV软X射线对锗测试图案进行成像时得到了证明。