Li Wei, Salanitri John, Tutton Sean, Dunkle Eugene E, Schneider Joseph R, Caprini Joseph A, Pierchala Linda N, Jacobs Paula M, Edelman Robert R
Department of Radiology, Center for Advanced Imaging, Evanston Northwestern Healthcare, Walgreen Building, Suite G507, 2650 Ridge Ave, Evanston, IL 60201, USA.
Radiology. 2007 Mar;242(3):873-81. doi: 10.1148/radiol.2423052101.
Institutional review board approval and informed consent were obtained for this HIPAA-compliant study, whose purpose was to prospectively evaluate the use of a dual-contrast mechanism in conjunction with an iron oxide blood pool contrast agent, ferumoxytol, to depict deep venous thrombosis (DVT). Nine patients with lower extremity DVT detected with duplex ultrasonography (US) were imaged with magnetic resonance (MR) imaging and ferumoxytol. Three techniques, including precontrast two-dimensional time-of-flight (TOF) imaging, ferumoxytol-enhanced bright-blood imaging, and ferumoxytol-enhanced dark-blood imaging, were applied. Image quality for precontrast and ferumoxytol-enhanced images was analyzed by using a four-point scale. Thrombus was depicted as a filling defect within the blood pool on bright-blood images and as bright tissue that appeared highly contrasted against a dark background on dark-blood images. Image quality of ferumoxytol-enhanced images was uniformly superior to that of precontrast TOF images (P = .007). Compared with precontrast TOF images, ferumoxytol-enhanced bright-blood images had higher contrast-to-noise ratios (CNRs) between thrombus and blood (P = .051), whereas ferumoxytol-enhanced dark-blood images showed significantly higher CNRs between thrombus and surrounding muscle (P = .008). Ferumoxytol-enhanced MR imaging can depict DVT with a dual-contrast mechanism and show the extent of thrombus.
本符合健康保险流通与责任法案(HIPAA)的研究获得了机构审查委员会的批准并取得了知情同意,其目的是前瞻性评估双对比机制联合氧化铁血池造影剂(ferumoxytol)用于描绘深静脉血栓形成(DVT)的情况。9例经双功超声(US)检测出下肢DVT的患者接受了磁共振(MR)成像及ferumoxytol检查。应用了三种技术,包括对比前二维时间飞跃(TOF)成像、ferumoxytol增强的亮血成像和ferumoxytol增强的黑血成像。采用四点量表分析对比前及ferumoxytol增强图像的图像质量。血栓在亮血图像上表现为血池内的充盈缺损,在黑血图像上表现为与暗背景形成高对比度的亮组织。ferumoxytol增强图像的图像质量均优于对比前TOF图像(P = 0.007)。与对比前TOF图像相比,ferumoxytol增强的亮血图像在血栓与血液之间具有更高的对比噪声比(CNR)(P = 0.051),而ferumoxytol增强的黑血图像在血栓与周围肌肉之间显示出显著更高的CNR(P = 0.008)。Ferumoxytol增强的MR成像可通过双对比机制描绘DVT并显示血栓范围。