Suppr超能文献

肩部、髋部和腕部的磁共振关节造影:随着注射至成像时间增加对造影剂动力学和图像质量的评估

MR arthrography of the shoulder, hip, and wrist: evaluation of contrast dynamics and image quality with increasing injection-to-imaging time.

作者信息

Andreisek Gustav, Duc Sylvain R, Froehlich Johannes M, Hodler Juerg, Weishaupt Dominik

机构信息

Institute for Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland.

出版信息

AJR Am J Roentgenol. 2007 Apr;188(4):1081-8. doi: 10.2214/AJR.06.0719.

Abstract

OBJECTIVE

The purpose of our study was to investigate the contrast dynamics and the relationship between visualization of intraarticular structures and time elapsed between intraarticular injection of contrast agent and MRI in symptomatic patients referred for MR arthrography of the shoulder, hip, and wrist.

SUBJECTS AND METHODS

Our local ethics committees and the national drug administration approved this multicentric study. We prospectively studied 11 shoulders, 11 hips, and 10 wrists. After the intraarticular gadolinium injection, patients underwent a baseline MR arthrography protocol (time point [TP] 1) and subsequent MRI at another four time points (TP 2-TP 5) up to 240 minutes. The course of contrast-to-noise ratio (CNR) over time was calculated. Three observers assessed the degree of visualization of different intraarticular structures and the overall image quality at each time point using a 3-point scale and a 5-point scale, respectively.

RESULTS

For all joints, CNR measurements showed peak CNR at TP 1 (21 minutes) and TP 2 (45 minutes) with a subsequent, near-logarithmic decline of CNR values over time. Visualization of different anatomic structures decreased over time. Overall image quality was insufficient for diagnostic purposes at TP 3 (96 minutes) in three (27%) of 11 shoulders and in three (27%) of 11 hips. In two (20%) of 10 wrists, image quality was insufficient at TP 2 (45 minutes).

CONCLUSION

For MR arthrography, the degree of visualization of intraarticular structures depends on the time elapsed between contrast injection and MRI. MR arthrography of the shoulder and hip should be performed within 90 minutes, and MR arthrography of the wrist should be performed within 45 minutes, after intraarticular injection.

摘要

目的

本研究旨在调查有症状患者在接受肩部、髋部和腕部磁共振关节造影检查时,关节内注射造影剂后造影剂动力学以及关节内结构可视化与磁共振成像(MRI)之间的时间关系。

受试者与方法

我们的研究获得了当地伦理委员会和国家药品管理部门的批准,为一项多中心研究。我们前瞻性地研究了11个肩部、11个髋部和10个腕部。关节内注射钆剂后,患者接受基线磁共振关节造影检查方案(时间点[TP]1),并在另外四个时间点(TP 2 - TP 5)进行后续MRI检查,最长至240分钟。计算了对比噪声比(CNR)随时间的变化过程。三名观察者分别使用3分制和5分制评估每个时间点不同关节内结构的可视化程度和整体图像质量。

结果

对于所有关节,CNR测量显示在TP 1(21分钟)和TP 2(45分钟)时CNR达到峰值,随后CNR值随时间呈近似对数下降。不同解剖结构的可视化程度随时间降低。在11个肩部中的3个(27%)和11个髋部中的3个(27%),在TP 3(96分钟)时整体图像质量不足以用于诊断目的。在10个腕部中的2个(20%),在TP 2(45分钟)时图像质量不足。

结论

对于磁共振关节造影,关节内结构的可视化程度取决于造影剂注射与MRI之间的时间间隔。关节内注射后,肩部和髋部的磁共振关节造影应在90分钟内进行,腕部的磁共振关节造影应在45分钟内进行。