Suppr超能文献

内镜鼻窦手术中微型清创器与标准器械的比较:一项双盲随机研究。

Comparing the microdebrider and standard instruments in endoscopic sinus surgery: a double-blind randomised study.

作者信息

Sauer M, Lemmens W, Vauterin T, Jorissen M

机构信息

Department of Otorhinolaryngology, University Hospitals Leuven, Belgium.

出版信息

B-ENT. 2007;3(1):1-7.

Abstract

UNLABELLED

Comparing the microdebrider and standard instruments in endoscopic sinus surgery: a double-blind randomised study.

OBJECTIVE

It is frequently stated that microdebriders provide better mucosal preservation in endoscopic sinus surgery (ESS), and therefore better and faster healing, when compared to the standard Blakesley instruments. However, evidence from comparative prospective studies is lacking. In this study, we compared the results of microdebriders with traditional surgical instruments for ESS.

METHODS

A prospective, randomised, comparative, double-blind study in 50 patients undergoing bilateral ESS. Each patient was operated on with both instruments: one side of the nose with the microdebrider only, and the other side with standard instruments. The outcome of surgery was measured by using a symptom score and an endoscopic score at five time points during the first six postoperative months.

RESULTS

Both instruments resulted in symptom improvement and in endoscopically visible healing over time, but no significant difference was found between the two techniques. In endoscopic evaluation, only the total score at 3 weeks after surgery was significantly better in the microdebrider group. No significant difference was found at any other time point. Synechia formation, patency of middle meatal antrostomy, and open access to the ethmoid were the same in both groups.

CONCLUSION

In this study of endoscopic sinus surgery the use of the microdebrider does not offer major advantages compared to the standard instruments.

摘要

未标注

内镜鼻窦手术中微型切割器与标准器械的比较:一项双盲随机研究

目的

人们常说,在内镜鼻窦手术(ESS)中,与标准的布莱克斯利器械相比,微型切割器能更好地保护黏膜,因此愈合更好更快。然而,缺乏来自比较性前瞻性研究的证据。在本研究中,我们比较了微型切割器与传统手术器械用于ESS的结果。

方法

对50例接受双侧ESS的患者进行一项前瞻性、随机、比较、双盲研究。每位患者均使用两种器械进行手术:一侧鼻腔仅使用微型切割器,另一侧使用标准器械。在术后前六个月的五个时间点,通过症状评分和内镜评分来衡量手术结果。

结果

随着时间推移,两种器械均使症状得到改善且内镜下可见愈合,但两种技术之间未发现显著差异。在内镜评估中,仅微型切割器组在术后3周时的总分显著更好。在其他任何时间点均未发现显著差异。两组的粘连形成、中鼻道上颌窦造口通畅情况以及筛窦开放情况相同。

结论

在这项内镜鼻窦手术研究中,与标准器械相比,使用微型切割器并无主要优势。